BOP HIPWR 091719
3-1
SECTION 3 - OPERATION
3.1
GENERAL
This section explains how to operate the 1000 Watt BOP Power Supply. The power supply can
be operated either in Local mode (see PAR’s. 3.2 and 3.3) using the front panel keypad,
ADJUST control and graphical display, or in Remote mode.
NOTE: Unless otherwise noted, operating instructions start from the power-up screen (see
either Figure 3-4 or Figure 3-5). Press
%
to exit submenus and return to the power-up
screen.
Remote mode can either be analog or digital. Analog remote uses analog signals from the Ana-
log I/O port to control the output (see PAR. 3.4).
•
MG Models.
Digital remote (see PAR. 3.5) for MG models uses either the built-in GPIB
(IEEE 488) (see PAR. 3.5.4) or RS 232 (see PAR. 3.5.6) interface to communicate with a
remote computer. GPIB or RS 232 communication is via one of two protocols: 1) SCPI
commands which afford full functionality of the BOP (see PAR. 3.6, Appendix A and
Appendix B) or 2) CIIL commands (for compatibility with older Kepco products). MG
model operation in remote mode can be simplified by the use of the VISA driver (see
PAR. 3.5.5).
•
ME Models.
Digital remote for ME models uses either the built-in LAN (see PAR. 3.5.7)
or RS 232 (see PAR. 3.5.6) interface to communicate with a remote computer. RS 232
communication is via one of two protocols: 1) SCPI commands which afford full function-
ality of the BOP (see PAR. 3.6, Appendix A and Appendix B) or 2) CIIL commands (for
compatibility with older Kepco products). LAN communication uses SCPI commands.
3.2
POWER SUPPLY BASICS
The following paragraphs describe basic operation of the front panel controls, which are used to
configure and operate the power supply. This includes a description of the keypad (PAR. 3.2.1),
graphical display (LCD (PAR. ), how to turn the unit on (PAR. 3.2.3), how to change the power-
up defaults (see PAR. 3.3.8). An explanation of the BOP menus (PAR. 3.2.4) provides basic
techniques needed to use the ADJUST control and the function, arrow and numeric keys in con-
junction with the LCD to operate the power supply. Operator convenience functions (LCD back-
ground and contrast, and the audible beep) are described in PAR. 3.2.5. Refer to Table 3-1 and
Figure 3-1 for a description of front panel controls and indicators.
Содержание BOP-ME 1KW
Страница 2: ......
Страница 20: ...xii BOP 1K 091719 FIGURE 1 1 HIGH POWER BOP SERIES POWER SUPPLY...
Страница 42: ......
Страница 64: ...2 22 BOP HIPWR 091719 FIGURE 2 11 PARALLEL CONFIGURATION LOCAL SENSING TYPICAL...
Страница 65: ...BOP HIPWR 091719 2 23 FIGURE 2 12 PARALLEL CONFIGURATION REMOTE SENSING TYPICAL...
Страница 76: ......
Страница 161: ...BOP HIPWR 091719 3 85 FIGURE 3 29 STATUS REPORTING STRUCTURE...
Страница 164: ......