B-28
BOP-1K 091719
B.94
[SOURce:]LIST:VOLTage COMMAND
LIST:VOLT
Short Form: LIST:VOLT[:LEV] <exp_value>, <exp_value>, . . . (to max of 5900 data points)
Long Form: LIST:VOLTage[:LEVel] <exp_value>, <exp_value>, . . . (to max of 5900 data points)
<exp_value> = digits with decimal point and Exponent, e.g., 2.71E1 for 27.1
Description:
Adds the voltage value (in Volts) to list.
This command sequentially adds LIST:VOLTage values to
the main channel List Data Table locations illustrated in Table B-3. LIST:CLE sets starting location to 0.
Next location indicated by LIST:VOLT:POIN? The maximum number of entries is 2950, 3933, or 5900.
Since the input buffer of the BOP has a limit of 253 characters, multiple commands are necessary to
complete the full 5900 entries of the list. If LIST:CURR has any entries, an error message: -221,”Set-
tings conflict” is posted in the error queue. Related Commands: LIST:VOLT:POIN?, FUNC:MODE,
LIST:CLE, *RST. (See example, Figure B-6.)
B.95
[SOURce:]LIST:VOLTage? QUERY
LIST:VOLT?
Syntax:
Short Form: LIST:VOLT?
Long Form: LIST:VOLTage?
Return Value: <value1>, <value2>, . . . to <value16>
Description:
Identifies the parameters (main channel) entered for the list.
Starting at location established by
LIST:QUERy, returns comma-separated list of up to 16 values indicating the main channel parameters
entered. i.e., the contents of the main channel locations of Table B-3. Related Commands: LIST:
VOLT, LIST:QUERy. If LIST:CURR has any entries, an error message: -221,”Settings conflict” is
posted in the error queue. (See example, Figure B-6.)
B.96
[SOURce:]LIST:VOLTage:APPLy COMMAND
LIST:VOLT:APPL
Syntax:
Short Form: LIST:VOLT:APPL <type>,<value1>,<value2>[,<value3>]
Long Form: LIST:VOLTage:APPLy <type>,<value1>,<value2>[,<value3>]
Where <type> is {SQUARE | RAMP+ | RAMP- | TRIANGLE | SINE | LEVEL | SLOPE}
<value1> is frequency in Hz, except period (duration) in seconds for LEVEL or end point (in
V* or A* for SLOPE.
<value2> is p-p amplitude in V* or A*, except amplitude (offset) in V* or A* for LEVEL. or time
in seconds for SLOPE.
<value3> is offset (optional, default is 0, not applicable to level)
* V (Volts) for voltage list, A (Amperes) for current list
Description:
Causes the unit to add a series of points to both the list:volt array and the list:dwell array to
make either a level or a waveform segment of one of six types.
Refer to table 3-12 for a descrip-
tion of the waveform types. Except for LEVEL and SLOPE, the waveform type specified is generated
at the frequency specified with a peak-to-peak amplitude centered on zero. If the optional offset value
is specified, the center of the generated series of points is moved off zero. For SLOPE, the segment
begins where the previous segment ends and reaches the specified end point within the time speci-
fied. The apply generator takes into account the soft limits for the voltage channel and insures the gen-
erated array does not exceed the unit’s capabilities.
B.97
[SOURce:]LIST:VOLTage:APPLy:SWEep COMMAND
LIST:VOLT:APPL:SWE
Syntax:
Short Form: LIST:VOLT:APPL:SWE <>,
Long Form: LIST:VOLTage:APPLy:SWEep <value1>,<value2>
Where <value1> is start angle. Valid from 0 to 359.99 degrees.
<value2> is stop angle. Valid from 0.01 to 360.00 degrees
Description:
Allows the user to provide a starting angle for either triangle and sine waveforms and an
optional stop angle.
If the stop angle is not supplied, the unit defaults to 360 degrees. This command
should be placed at the beginning of the waveform program to be applicable to all sine and triangle
waveform segments.
B.98
[SOURce:]LIST:VOLTage:APPLy:SWEep? QUERY
LIST:VOLT:APPL:SWE?
Syntax:
Short Form: LIST:VOLT:APPL:SWE? Long Form: LIST:VOLTage:APPLy:SWEep?
Return Value: <value1>, <value2>(0.01 to 360)
Description:
Returns start
<value1>
and stop
<value2>
angle in degrees for either triangle and sine wave-
forms.
Содержание BOP-ME 1KW
Страница 2: ......
Страница 20: ...xii BOP 1K 091719 FIGURE 1 1 HIGH POWER BOP SERIES POWER SUPPLY...
Страница 42: ......
Страница 64: ...2 22 BOP HIPWR 091719 FIGURE 2 11 PARALLEL CONFIGURATION LOCAL SENSING TYPICAL...
Страница 65: ...BOP HIPWR 091719 2 23 FIGURE 2 12 PARALLEL CONFIGURATION REMOTE SENSING TYPICAL...
Страница 76: ......
Страница 161: ...BOP HIPWR 091719 3 85 FIGURE 3 29 STATUS REPORTING STRUCTURE...
Страница 164: ......