3-76
BOP HIPWR 091719
An optional offset can be added to the command to cause the BOP to generate a non-centered
waveform. For example, a 5 volt 400 Hertz sine wave may be centered at -3 volts. The list sub-
system has controls the allow the user to modify the unit's behavior to generate parts of wave-
forms and to used specific dwell times as appropriate. The APPLY subsystem accommodates
122 different segments in a single waveform provided the generated points fit in the array. See
paragraph 3.3.10.3 for an explanation of how a waveform is generated by the BOP.
FIGURE 3-27. TREE DIAGRAM OF SCPI COMMANDS USED WITH BOP POWER SUPPLY (SHEET 1 OF 2)
ABORt subsystem
ABORt
INITiate subsystem
INITiate
[:IMMediate]
:CONTinuous bool
:CONTinuous?
CALibrate subsystem
CALibrate
:CEXTernal MAX, ZERO
:CGAin MIN MAX
:CLIMit MAX, ZERO
:CPRotect MIN, MAX
:CURRent MIN, MAX
:DATA val
:SAVE <string>
:STATe <boolean>, password
:STATe?
:VEXTernal MAX, ZERO
:VOLTage MIN, MAX
:VGAin MIN, MAX
:VLIMit MAX, ZERO
:VPRotect MIN, MAX
:ZERO
OUTPut subsystem
OUTPut
[:STATe] ON or OFF
[:STATe]?
:CONT
:CONT?
:MODE ACTIVE, RESISTIVE,
BATTERY
:MODE?
MEMory subsystem
MEMory
:PACK
:LOC
:LOC?
:UPDate
ROOT :
(colon)
SYSTem subsystem
SYSTem
:BEEP
:COMM
:GPIB:ADDR val
:GPIB:ADDR?
:SER
:BAUD
:BAUD?
:ECHO
:ECHO?
:PACE
:PACE?
:PROM
:PROM?
:ERRor?
[:NEXT]?
:CODE?
[:NEXT]?
:ALL?
:KEYBoard ENABLE DISABLE
:KEYBoard?
MODE
MODE?
:PASSword
[:CENAble] (code)
:STATe?
:CDISenable (code)
:NEW OLD, NEW
:STATe?
:REMote bool
:REMote?
:SECUrity
:IMMediate
:SET
:SET?
:VERSion?
LIST subsystem
(See Sheet 2)
STATus subsystem
STATus
:OPERation
:CONDition?
:ENABle val
:ENABle?
[:EVENt]?
:PRESet
:QUEStionable
:CONDition?
:ENABle val
:ENABle?
[:EVENt]?
TRIGger subsystem
TRIGger
[:SOURce] EXT, BUS
[:SOURce]?
MEASure subsystem
MEASure
[:SCALar][:DC]?
[:SCALar]:[CURRent][:DC]?
[:SCALar]:[MODE][:DC]
[:SCALar]:[RATE][:DC]
[:SCALar]:[RATE][:DC]?
[:SCALar]:[VOLTage][:DC]?
[:SCALar]:[TRANsient][:DC]?
[SOURce:] subsystem
(see Sheet 2)
See PAR. 3.5.2.2 and Figure 3-20 for special programming considerations.
Requires MEM:UPD to save for power-up.
Содержание BOP-ME 1KW
Страница 2: ......
Страница 20: ...xii BOP 1K 091719 FIGURE 1 1 HIGH POWER BOP SERIES POWER SUPPLY...
Страница 42: ......
Страница 64: ...2 22 BOP HIPWR 091719 FIGURE 2 11 PARALLEL CONFIGURATION LOCAL SENSING TYPICAL...
Страница 65: ...BOP HIPWR 091719 2 23 FIGURE 2 12 PARALLEL CONFIGURATION REMOTE SENSING TYPICAL...
Страница 76: ......
Страница 161: ...BOP HIPWR 091719 3 85 FIGURE 3 29 STATUS REPORTING STRUCTURE...
Страница 164: ......