BOP HIPWR 091719
3-5
FIGURE 3-4. POWER-UP SCREEN SHOWING GRAPHIC METERS
FIGURE 3-5. POWER-UP SCREEN SHOWING TIME LINE GRAPH
The OPERATING INFO found in the upper right of the display consists of three lines. The
Selected mode of operation is shown on the top line. If the unit is providing power to the load
(SOURCE) or absorbing power from the load (SINK), this is displayed on the Middle line. If the
the unit is at a protection limit, the third line is displayed.
When in Voltage mode, the power supply will (within the configured and rated limits) provide the
programmed output voltage. Mode displayed at the upper right is VOLTAGE. Current is deter-
mined by the load, and cannot exceed the Current Protect limits. If the protect limit is reached,
CPROTECT is displayed; if protect limit has not been reached this line is blank.
VOLTAGE
SOURCE
0.0402
0.0000
ANALOG VOLTMETER
DIGITAL VOLTMETER
ANALOG AMMETER
DIGITAL AMMETER
HIGHLIGHT TO CHANGE
LOCAL/REMOTE
OPERATING
INFO
SOFTWARE
FUNCTION
KEYS
STATUS
ACTIVE SETTINGS
MESSAGES
LAN OK
VOLTAGE
0000
0.
NOTE:
WHEN SET TO BIPOLAR, ONLY ONE PROTECTION FIELD IS DISPLAYED.
WHEN SET TO INDEPENDENT, TWO PROTECTION FIELDS ARE DISPLAYED AS SHOWN HERE.
SEE PAR. 3.3.3.1 FOR DETAILS.
VOLTAGE
SINK
-9.3600
-10.000
ACTUAL OUTPUT
CURRENT WAVEFORM
ACTUAL OUTPUT
VOLTAGE WAVEFORM
VOLTAGE
0000
-10.0
Содержание BOP-ME 1KW
Страница 2: ......
Страница 20: ...xii BOP 1K 091719 FIGURE 1 1 HIGH POWER BOP SERIES POWER SUPPLY...
Страница 42: ......
Страница 64: ...2 22 BOP HIPWR 091719 FIGURE 2 11 PARALLEL CONFIGURATION LOCAL SENSING TYPICAL...
Страница 65: ...BOP HIPWR 091719 2 23 FIGURE 2 12 PARALLEL CONFIGURATION REMOTE SENSING TYPICAL...
Страница 76: ......
Страница 161: ...BOP HIPWR 091719 3 85 FIGURE 3 29 STATUS REPORTING STRUCTURE...
Страница 164: ......