BOP-1K 091719
B-41
B.160 SYSTem:ERRor:CODE? QUERY
SYST:ERR:CODE?
Syntax
:
Short Form: SYST:ERR:CODE?
Long Form: SYSTem:ERRor:CODE?
Description:
Returns the three character error code without the ASCII definition string.
The error codes are
defined in table B-6 (See example, Figure B-14.)
B.161 SYSTem:ERRor:CODE:ALL? QUERY
SYST:ERR:CODE:ALL?
Syntax
:
Short Form: SYST:ERR:CODE:ALL?
Long Form: SYSTem:ERRor:CODE:ALL?
Return Value:
Description:
Returns a comma-separated list of all error codes.
A maximum of 31 codes will be returned; if the
queue is empty, the power supply returns 0.
B.162 SYSTem:KEYBoard COMMAND
SYST:KEYB
Syntax:
Short Form: SYST:KEYB [DIS | ENAB]
Long Form: SYSTem:KEYBoard [DISable | ENABle]
Description:
Locks (DIS) or unlocks (ENAB) the front panel keypad.
B.163 SYSTem:KEYBoard? QUERY
SYST:KEYB?
Syntax:
Short Form: SYST:KEYB?
Long Form: SYSTem:KEYBoard?
Returns: 1 or 0
Description:
Identifies the state of the keypad: locked (1) or unlocked (0).
B.164 SYSTem:MDNS? QUERY
SYST:MDNS?
[ME MODELS ONLY]
Syntax:
Short Form: SYST:MDNS?
Long Form: SYSTem:MDNS?
Returns: <hostname> where <hostname> = a string comprised of the MDNS Name + unit serial num-
ber + index number
Description:
Returns MDNS hostname.
Index number is not appended to the serial number if the index is 1.
Example:
SYST:MDNS? returns BOP_10_100_E12345602 for a BOP 10-100ME with a serial number of
E123456 and an index of 2. Returns BOP_10_100_E1234560 if index is 1.
B.165 SYSTem:MDNS:INDex COMMAND
SYST:MDNS:IND
[ME MODELS ONLY]
Syntax
:
Short Form: SYST:MDNS:IND nn
Long Form: SYSTem:MDNS:INDex<hostname>
where nn = integer between 1 and 99.
Description:
Sets the index number portion of the MDNS Hostname.
Index number (1 through 99) is automati-
cally assigned: 1 for first unit found, subsequent identical units are assigned sequential index numbers
to make the Host Name and Index a unique identifier. May be changed to an unused number between
1 and 99 if desired.
B.166 SYSTem:MDNS:IND? QUERY
SYST:MDNS:IND?
[ME MODELS ONLY]
Syntax:
Short Form: SYST:MDNS:IND?
Long Form: SYSTem:MDNS:INDex?
Returns: integer from 1 to 99
Description:
Returns MDNS index number.
B.167 SYSTem:MDNS:NAME COMMAND
SYST:MDNS:NAME
[ME MODELS ONLY]
Syntax
:
Short Form: SYST:MDNS:NAME <hostname> Long Form: SYSTem:MDNS:NAME <hostname>
where <hostname> = up to 12 ASCII characters
Description:
Sets the 12 character MDNS Hostname field.
Default host name is model_V_A (e.g., BOP_10_100
for BOP 10-100ME). Host Name can be changed as the user desires. Up to 12 ASCII characters are
permitted.
Содержание BOP-ME 1KW
Страница 2: ......
Страница 20: ...xii BOP 1K 091719 FIGURE 1 1 HIGH POWER BOP SERIES POWER SUPPLY...
Страница 42: ......
Страница 64: ...2 22 BOP HIPWR 091719 FIGURE 2 11 PARALLEL CONFIGURATION LOCAL SENSING TYPICAL...
Страница 65: ...BOP HIPWR 091719 2 23 FIGURE 2 12 PARALLEL CONFIGURATION REMOTE SENSING TYPICAL...
Страница 76: ......
Страница 161: ...BOP HIPWR 091719 3 85 FIGURE 3 29 STATUS REPORTING STRUCTURE...
Страница 164: ......