BOP HIPWR 091719
3-13
TABLE 3-3. DISPLAY SETTINGS (OPERATOR CONVENIENCE) MENU
SETTING
CHOICES
(
BOLD
= Factory
Default)
FUNCTION
NOTE: To save any of the functions listed below for power-up it is necessary to first change SAVE DISPLAY CHG at the password
setup (see PAR. 3.2.4.2and Figure 3-6) from DISABLE to ENABLE.
Graphic Display
Meters
75s
30s
15s
7.5s
3.8s
1.5s
0.8s
0.5s
0.3s
0.15s
Meters
- Output voltage and current are displayed on representations of analog
meters.
75s
through
0.15s
- Displays a graph showing a sample of the output for the
time indicated (see Figure 3-5). The complete time-line uses 240 points. E.g.,
selecting 2 Second Graph means that 2S/240 = 50ms sampling, i.e., every
50ms a snapshot of the output state is used to produce a single point.
Display Background
BLACK
WHITE
MonoBlack
BLUE
GREEN
Lt.Green
Lt.Blue
BLACK
- Sets the background to black and displays white characters plus color
for voltage and current and special messages and warnings.
WHITE
- Sets the background to white and displays black characters plus color
for voltage, current, special messages and warnings.
MonoBlack
- Sets background and characters to either white or black only.
BLUE
- Sets the background to blue and displays black characters plus color
for voltage, current, special messages and warnings.
GREEN
- Sets the background to green and displays red characters plus color
for voltage, current, special messages and warnings.
Lt.Green
- Sets the background to light green and displays black characters
plus color for voltage, current, special messages and warnings.
Lt.Blue
- Sets the background to light blue and displays black characters plus
color for voltage, current, special messages and warnings.
Protect Entry
Independent
Bipolar
Independent
- and – protection limits to be set independently. from
the front panel (see PAR. 3.3.3.1 for considerations when using remote mode).
Bipolar
- Causes a single protection limit value (one for voltage, one for cur-
rent) to apply to both ± limits. Only one value is displayed and edited from the
front panel. (see PAR. 3.3.3.1.)
Waveform Stop
Output OFF
User Option
#
Stop Immediate
$
Stop & End Cycle
%
Output OFF
Output OFF
- When waveform is stopped (either count complete or
%
pressed), output freezes at whatever level the waveform was at when
%
was
pressed or count completed, then after a brief delay output is set to STANDBY
(disabled).
User Option
- Allows three choices during waveform execution
1. Press
#
to select
Stop Immediate
- When waveform is stopped (
%
pressed), output freezes at whatever level the waveform was at when
%
was
pressed.
2. Press
$
to select
Stop and End Cycle
- When waveform is stopped
(either count complete or
%
pressed), waveform runs through full cycle. The
output stops at the last generated value of the waveform (e.g., for a sinewave
segment of 0° to 270°, 10V amplitude, 0V offset, when
%
is pressed the out-
put will end up at -10V).
3. Press
%
to select
Output OFF
. This is the same as Output OFF described
above,
Key Press Beep
On
Error Only
Off
On
- provides an audible beep for each key press and for each error received.
Error Only
- silences the beeps for each key press; errors will still cause beep.
Off
- silences all beeps including key presses and errors except for power-up
and unit faults.
CONTRAST
---
Use number keys 0 through 9 for coarse adjust. Use
T
and
R
for fine
adjust. Then press (
%
to exit or
$
to save for power up (see PAR. 3.2.5.1).
Содержание BOP-ME 1KW
Страница 2: ......
Страница 20: ...xii BOP 1K 091719 FIGURE 1 1 HIGH POWER BOP SERIES POWER SUPPLY...
Страница 42: ......
Страница 64: ...2 22 BOP HIPWR 091719 FIGURE 2 11 PARALLEL CONFIGURATION LOCAL SENSING TYPICAL...
Страница 65: ...BOP HIPWR 091719 2 23 FIGURE 2 12 PARALLEL CONFIGURATION REMOTE SENSING TYPICAL...
Страница 76: ......
Страница 161: ...BOP HIPWR 091719 3 85 FIGURE 3 29 STATUS REPORTING STRUCTURE...
Страница 164: ......