BOP HIPWR 091719
2-13
2.7
SETTING UP THE UNIT
The following paragraphs describe the connections and initial BOP setup needed to operate in
the desired mode.
2.7.1
CONSIDER THE LOAD TYPE
The BOP can be configured to respond differently to the Output OFF command, depending on
whether the load is defined as Active, Resistive or Battery. Refer to PAR. 3.3.7 to configure this
setting.
2.7.2
SETUP FOR LOCAL OPERATION
With all power off, connect the load to the BOP using either local or remote sensing (refer to
PAR. 2.5). If units are to be connected in series or parallel, refer to PAR. 2.7.6.2.) Then refer to
PAR. 3.2 for power supply basics and local operation. The factory default configuration allows
local operation with no further setup required.
FIGURE 2-3. LOAD CONNECTIONS, LOCAL SENSING