BOP HIPWR 091719
2-5
TABLE 2-7. PARALLEL/SERIAL CONTROL IN PORT PIN ASSIGNMENTS
CONNECTOR
PIN
SIGNAL NAME
FUNCTION
PARALLEL/SERIAL
CONTROL IN PORT
(A2A5J3)
1
SGND
Local signal ground
2
No connection
3
S_IN_PARALLEL
Input for programming output current of a parallel-connected slave. Pro-
vided by master unit.
Level: –10V to +10V controls the current between –IOnom to +IOnom.
4
No connection
5
No connection
6
IOUT_M_UNIT
Output for programming slave current when the unit is a parallel-con-
nected master
Level: –10V to +10V programs slave current to –IOnom to +IOnom.
7
No connection
8
S_IN_SERIAL
Input for programming output voltage of a series-connected slave. Pro-
vided by master unit or from previous slave if multiple slaves connected.
Level: –EOnom to +EOnom controls programs output voltage from
+EOnom to –EOnom.
TABLE 2-8. PARALLEL/SERIAL PROTECT IN PORT PIN ASSIGNMENTS
CONNECTOR
PIN
SIGNAL NAME
FUNCTION
PARALLEL/SERIAL
PROTECT IN PORT
(A2A5J1)
1
SD_A
Anode of LED optocoupler which is part of protection circuit for parallel
or series combination. Cathode of LED is connected to PARALLEL/
SERIAL PROTECT OUT PORT (A2A5J2) pin 1 (see Table 2-9). When
activated, the optocoupler shuts down the unit. LEDs from all units of the
parallel or series combination are connected in series.
2
PGOUT_C
Collector of optocoupler transistor which is part of protection circuit for
parallel or series combination. Transistor emitter is connected to PARAL-
LEL/SERIAL PROTECT OUT PORT (A2A5J2) pin 2 (see Table 2-9).
When unit is operating normally, transistor is saturated. Transistors from
all units of the parallel or series combination are connected in series.
3
SD_RETURN
Completes return connection for the protection circuit which receives
energy from the master unit.
4
No connection
5
No connection
6
FAIL SAFE
This input can be used as a fail safe/interlock protection. When enabled,
a short between pins 6 and 7 (GND) is required for the unit to operate.
Refer to PAR. 2.7.3 for details and to enable the feature..
7
GND
Local power ground.
8
ALLOW EXT_ERR
Provides energy for the protection circuit (master unit only). Disabled at
power up to prevent shutdown during power up.
TABLE 2-9. PARALLEL/SERIAL PROTECT OUT PORT PIN ASSIGNMENTS
CONNECTOR
PIN
SIGNAL NAME
FUNCTION
PARALLEL/SERIAL
PROTECT OUT
PORT
(A2A5J2)
1
SD_K
Cathode of LED optocoupler which is part of protection circuit for parallel
or series combination. (See IN port (A2A5J1) pin 1,Table 2-8.)
2
PGOUT_E
Emitter of optocoupler transistor which is part of protection circuit for
parallel or series combination. (See IN port (A2A5J1) pin 2,Table 2-8.)
3
SD_RETURN
Relayed connection, provides return for the protection circuit which
receives energy from the master unit.
4
No connection
5
No connection
6
No connection
7
No connection
8
No connection
Содержание BOP-ME 1KW
Страница 2: ......
Страница 20: ...xii BOP 1K 091719 FIGURE 1 1 HIGH POWER BOP SERIES POWER SUPPLY...
Страница 42: ......
Страница 64: ...2 22 BOP HIPWR 091719 FIGURE 2 11 PARALLEL CONFIGURATION LOCAL SENSING TYPICAL...
Страница 65: ...BOP HIPWR 091719 2 23 FIGURE 2 12 PARALLEL CONFIGURATION REMOTE SENSING TYPICAL...
Страница 76: ......
Страница 161: ...BOP HIPWR 091719 3 85 FIGURE 3 29 STATUS REPORTING STRUCTURE...
Страница 164: ......