BOP HIPWR 091719
3-9
•
To change a numeric setting, press the number keys, then press
ENTER
to program the
numbers entered. Use the
CLEAR key
to clear numbers entered and start over.
•
To change a main channel (voltage or current) or Protect value with the units digit high-
lighted, press the number keys, (from most significant to least significant digit) including
the decimal point when needed, then press
ENTER
to apply the change or press the
Y
or
U
key to abort the change.
•
The
ADJUST
control can also be used to increment or decrement the highlighted digit.
Pressing
ADJUST
while rotating adjusts the least significant digit. If the output is on (unit
not in Standby) while changing main channel or Protect values, changes made using the
ADJUST
control are immediately applied to the output.
•
For alphanumeric characters, first use the
T
and
R
keys to highlight the desired char-
acter, then use the
U
or
Y
keys or
ADJUST
control to scroll through numbers, letters
and symbols. Then use the
T
and
R
keys to highlight the next character and repeat.
Use the
CLEAR
key to clear the entire alphanumeric field and start over. As an alterna-
tive, use multiple presses of the keys for letters or symbols:
0
(0, space),
1
(1, /, \),
2
(ABC),
3
(DEF),
4
(GHI),
5
(JKL),
6
(MNO).
7
(PQRS),
8
(TUV),
9
(WXYZ),
.
(., ;),
(+, -). Use the
T
key to highlight the next character.
3. Press
$
to apply the change and return to the menu (to change another parameter, repeat
steps 1 and 2). To abort (return to the menu without applying the change), press
%
.
NOTE: Press
HELP
key for more information, press
HELP
again to see multiple screens;
press
CLEAR
key to exit the help screen.
3.2.4.2
PASSWORD SETUP.
Parameters that can be protected may be designated as Unprotected (no password required) or
assigned one of three possible passwords: Main Unit, Admin 1 and Admin 2. The three pass-
words can be used to independently protect certain settings to prevent tampering or inadvertent
reconfiguration of the BOP, yet allow access to qualified personnel.
These password levels
apply only to local operation.
When in remote, only the main password is accessible, acting
as a general password (see PAR B.173)
.
The functions that can be password protected are
Interface settings, Max/Min settings, Load type, Test, Calibration, Power-up Settings, and Key-
pad lockout at power-up (see Figure 3-6 for factory default password settings). In addition, it is
possible to prevent changes made to the display settings from being saved for power up by set-
ting Save Display Chg to Disable.
When the unit is operating in remote mode with Keypad @ local activated, a password is
required before the unit can be returned to local operation. In addition, when a waveform is exe-
cuting in local mode, depressing
%
to stop the waveform requires a password before the
waveform is stopped.
To change any password you must enter the Admin 2 password to access the Password Menu.
The unit is shipped with the Admin 2 password set to “
KEPCO
,” the Main Unit password set to
”
DEFAULT
,” and the Admin 1 password is not assigned. To change the password or to protect
one of the protected menus, proceed as follows:
1. Press
%
from the power-up screen to enter the General Setup menu. Highlight Password
and press
!
.
Содержание BOP-ME 1KW
Страница 2: ......
Страница 20: ...xii BOP 1K 091719 FIGURE 1 1 HIGH POWER BOP SERIES POWER SUPPLY...
Страница 42: ......
Страница 64: ...2 22 BOP HIPWR 091719 FIGURE 2 11 PARALLEL CONFIGURATION LOCAL SENSING TYPICAL...
Страница 65: ...BOP HIPWR 091719 2 23 FIGURE 2 12 PARALLEL CONFIGURATION REMOTE SENSING TYPICAL...
Страница 76: ......
Страница 161: ...BOP HIPWR 091719 3 85 FIGURE 3 29 STATUS REPORTING STRUCTURE...
Страница 164: ......