BOP HIPWR 091719
2-15
Another example is to apply the short via a remote NC relay contact closure so that if either the
remote relay deenergizes, or the Parallel/Serial Protect In Port mating connector becomes
unplugged, the unit shuts down and the red FAULT LED will be lit.
FIGURE 2-5. FAIL SAFE FEATURE, SIMPLIFIED SCHEMATIC DIAGRAM
2.7.4
SETUP FOR REMOTE OPERATION VIA GPIB (MG MODELS ONLY)
With all power off, connect the load to the BOP using either local or remote sensing. If units are
to be connected in series or parallel, refer to PAR. 2.7.6.2. Connect the GPIB connector to the
GPIB port (see Figure 2-1 and Table 2-1). Turn power on and refer to PAR. 3.2 for power supply
basics and PAR. 3.5 for remote mode programming.
CAUTION: To ensure correct operation, do not remove the GPIB cable from the BOP
after a Query is processed. Ensure that the last command is a non-query
such as *CLS before removing the GPIB cable. Otherwise, power to the BOP
and/or the host computer may need to be cycled OFF then ON to restore
proper operation.
The default GPIB address is 6; to change it refer to PAR 3.5.3.2. The default configuration
allows both local and remote operation; to prevent local operation once the unit is being con-
trolled from the GPIB, see PAR. B.162. Refer to PAR. 3.5.3.2 to configure the GPIB Port.
SCPI programming is described in PAR. 3.6; Appendices A and B provide syntax for SCPI com-
mon and subsystem commands and queries implemented in this unit. All the features described
for Local Mode operation can be accomplished using remote SCPI commands.
2.7.5
SETUP FOR REMOTE OPERATION VIA RS 232C
With all power off, connect the load to the BOP using either local or remote sensing (refer to
PAR. 2.5). If units are to be connected in series or parallel, refer to PAR. 2.7.6.2. Connect the
RS 232 connector to the RS 232 port (see Figure 2-1 and Table 2-1). Turn power on and refer to
PAR. 3.2 power supply basics and PAR. 3.5.6 for RS 232 operation. SCPI programming is
described in PAR. 3.2; Appendices A and B provide syntax for SCPI common and subsystem
commands and queries implemented in this unit. Refer to PAR. 3.5.3.3 to configure the RS 232
Port.
Содержание BOP-ME 1KW
Страница 2: ......
Страница 20: ...xii BOP 1K 091719 FIGURE 1 1 HIGH POWER BOP SERIES POWER SUPPLY...
Страница 42: ......
Страница 64: ...2 22 BOP HIPWR 091719 FIGURE 2 11 PARALLEL CONFIGURATION LOCAL SENSING TYPICAL...
Страница 65: ...BOP HIPWR 091719 2 23 FIGURE 2 12 PARALLEL CONFIGURATION REMOTE SENSING TYPICAL...
Страница 76: ......
Страница 161: ...BOP HIPWR 091719 3 85 FIGURE 3 29 STATUS REPORTING STRUCTURE...
Страница 164: ......