2-30
BOP HIPWR 091719
The power-up sequence continues as “Enabling External Protections” and “Checking for Faults
in System” is displayed. When power-up is complete Slave status changes to “Ready” and the
yellow Standby LED on slaves goes out, indicating the slave is online. If the status of a slave
stays at “Standby” or changes to “Faulted,” the slave has not successfully powered up; a chirp-
ing noise can be heard as the unit repeated attempts to power-up. If this does not stop, turn off
power and remove the faulted slave from the system.
If all the slaves are recognized as ready, after no longer than 15 seconds maximum the master
LCD reverts to the Power On Default screen (see Figure 2-17). The slaves display the Slave
Power On Default screen (see Figure 2-18), except the unit will be in Current Mode for parallel
configurations and Voltage mode for series configurations and the message will indicate the unit
is operating as a slave. The slave number appears at the lower right of the display. For instruc-
tions to return the slave to standalone operation, refer to PAR. 2.8.7. The fault indicators on all
units are off.
FIGURE 2-16. MASTER POWER UP SCREEN
TABLE 2-13. SLAVE STATUS MESSAGE DEFINITIONS
Slave Status Message
Displayed on Master Power Up Screen
(see Figure 2-16)
MEANING
Ready
Unit is ready for operation.
STANDBY
If unit’s FAULT indicator is off, hardware error has NOT been detected, output is
ready to be turned on
No Answer
Unit is not responding to polls via BITBUS.
Faulted
Unit’s FAULT indicator is on to indicate a hardware error has been detected.
Not Used
Unit is not part of parallel configuration
Unknown
Waiting for interface communication
Mode Error
Slave does not match parallel/series configuration expected by master.
Unit Error
Slave does match the voltage or current configuration expected by master. In
Series 2x2 and 2x3 configurations all units must match voltage and current spec-
ifications. In some parallel systems the power supplies can have different current
capabilities. e.g., BOP 10-75MG and BOP 10-100MG can be mixed.
VOLTAGE
SOURCE
CPROTECT
VOLTAGE
CURRENT
Содержание BOP-ME 1KW
Страница 2: ......
Страница 20: ...xii BOP 1K 091719 FIGURE 1 1 HIGH POWER BOP SERIES POWER SUPPLY...
Страница 42: ......
Страница 64: ...2 22 BOP HIPWR 091719 FIGURE 2 11 PARALLEL CONFIGURATION LOCAL SENSING TYPICAL...
Страница 65: ...BOP HIPWR 091719 2 23 FIGURE 2 12 PARALLEL CONFIGURATION REMOTE SENSING TYPICAL...
Страница 76: ......
Страница 161: ...BOP HIPWR 091719 3 85 FIGURE 3 29 STATUS REPORTING STRUCTURE...
Страница 164: ......