![Infineon XDPP1100 Скачать руководство пользователя страница 89](http://html1.mh-extra.com/html/infineon/xdpp1100/xdpp1100_technical-reference-manual_2055193089.webp)
User Manual
89 of 562
V 1.0
2021-08-25
XDPP1100 technical reference manual
Digital power controller
Voltage control
Peripheral Field name
Access Address
Bits
Description
F3db(MHz) = [kfp/(1-kfp)] * 25 MHz /
2 * pi
vcontrol
vc_vramp_target
RW
7000_1404h
(vcontrol0)
7000_1804h
(vcontrol1)
[14:0]
Ramp target value referenced to
VSEN input (i.e., after scaling by
VOUT_SCALE_LOOP). Note that
while digitally this command can
handle a wider range, the target
value is limited to 2.1 V by the
analog circuitry.
Computed by FW from PMBus
commands as follows:
vc_vramp_target(U12.3) =
VOUT_COMMAND(U16-X.X) *
VOUT_SCALE_LOOP(U0.16) * 6400 /
(2^X * 2^16)
where, X = negative of VOUT_MODE
exponent
Note:
VOUT_COMMAND above may
be replaced with
VOUT_MARGIN_HIGH or
VOUT_MARGIN_LOW based on
OPERATION setting
LSB = 0.15625 mV, range = 0.0 to
2.1 V
vcontrol
vc_vramp_target_windo
w
RW
7000_1404h
(vcontrol0)
7000_1804h
(vcontrol1)
[22:15] Ramp target window, used to
define interrupt prior to reaching
ramp target (e.g., during soft-start
may be used by FW to enable SR
FETs prior to reaching final target).
LSB = 1.25 mV, range = 0.0 to
318.75 mV
vcontrol
vc_vramp_load_immedi
ate
RW
7000_1404h
(vcontrol0)
7000_1804h
(vcontrol1)
[23]
Immediately loads
vc_vramp_target into ramp output
when high. Otherwise the ramp
output is slewed to
vc_vramp_target at a rate
determined by vc_vramp_tstep.
The typical use for this field is
during pre-bias start-up. The pre-
bias voltage can be immediately
loaded into the ramp to define the
ramp start voltage, then the target
voltage (e.g., VOUT_COMMAND) can
be set on vc_vramp_target with
load_immediate set low to slew to
the final voltage.
0: Slew ramp output to
vc_vramp_target
1: Immediately set ramp output to
vc_vramp_target