User Manual
165 of 562
V 1.0
2021-08-25
XDPP1100 technical reference manual
Digital power controller
Digital pulse width modulator
Peripheral Field name
Access Address
Bits
Description
2: Loop 1, phase 0
3: Loop 0, phase 1
pwm
pwm10_loop_map
RW
7000_2C10h [19:18]
Defines the loop and phase
mapping of the PWM10 output.
0: PWM not in use
1: Loop 0, phase 0
2: Loop 1, phase 0
3: Loop 0, phase 1
pwm
pwm11_loop_map
RW
7000_2C10h [21:20]
Defines the loop and phase
mapping of the PWM11 output.
0: PWM not in use
1: Loop 0, phase 0
2: Loop 1, phase 0
3: Loop 0, phase 1
pwm
pwm12_loop_map
RW
7000_2C10h [23:22]
Defines the loop and phase
mapping of the PWM12 output.
0: PWM not in use
1: Loop 0, phase 0
2: Loop 1, phase 0
3: Loop 0, phase 1
pwm
ramp0_dc_max_nom RW
7000_2C14h [7:0]
ramp0 nominal max. duty cycle
scaled by the rectification voltage
(V
RECT
). The PMBus command
MAX_DUTY defines a fixed max.
duty-cycle limit. This parameter
defines a variable max. duty-cycle
limit that scales with the
rectification voltage. The lower of
the two limits will be enforced. This
max. duty cycle limit is scaled with
respect to the V
ref
reference defined
by parameter pid0.pid_vrect_ref as
shown below.
Max. duty = ramp0_dc_max_nom *
pid_vrect_ref/V
RECT
A setting of 0 will disable the scaled
max. duty-cycle limit and only
MAX_DUTY will apply.
LSB = 0.5 percent, range = 0.0 to
99.5 percent
pwm
ramp1_dc_max_nom RW
7000_2C14h [15:8]
ramp1 nominal max. duty cycle
scaled by the rectification voltage
(V
RECT
). The PMBus command
MAX_DUTY defines a fixed max.
duty-cycle limit. This parameter
defines a variable max. duty-cycle
limit that scales with the
rectification voltage. The lower of
the two limits will be enforced. This