XDPP1100 technical reference manual
Digital power controller
Digital pulse width modulator
Peripheral Field name
Access Address
Bits
Description
7000_2010h
(pid1)
as
V
err
= (target voltage - sense voltage)
When (V
err
is less than
pid_ovs_entry_thrs) AND (V
err
slope
is less than
pid_ovs_slope_entry_thrs) the
control loop enters OVS mode.
Notes:
1. This threshold is always negative,
indicating that the controller enters
OVS mode only when the sensed
voltage is above the target.
2. Setting pid_ovs_entry_thrs = 0
disables OVS mode.
3. There is a -1.25 mV offset (i.e.,
code 0 = -1.25 mV, 1 = -2.5 mV ...)
LSB = -1.25 mV, range = -1.25 to -
160 mV at VSEN
pid
pid_ovs_slope_entry
_thrs
RW
7000_1C10h
(pid0)
7000_2010h
(pid1)
[27:21]
OVS mode error voltage (V
err
) slope
entry threshold where the error
voltage is defined as
V
err
= (target voltage - sense voltage)
When (V
err
is less than
pid_ovs_entry_thrs) AND (V
err
slope
is less than
pid_ovs_slope_entry_thrs) the
control loop enters OVS mode.
Notes:
1. This threshold is always negative,
indicating that the controller enters
OVS mode as the sensed voltage is
increasing toward maximum
overshoot.
2. There is a -1.25 mV offset (i.e.,
code 0 = -1.25 mV, 1 = -2.5 mV ...)
LSB = 1.25 mV/clk, range = 0.0 to
158.75 mV/clk at VSEN
pid
pid_burst_mode_err
_thr
RW
7000_1C14h
(pid0)
7000_2014h
(pid1)
[3:0]
BM V
err
threshold where the V
err
is
defined as
V
err
= (target voltage - sense voltage)
When the controller is in BM (V
err
is
less than pid_burst_mode_err_thr),
it will trigger the start of a new
burst sequence.
Note:
This threshold is always positive,
indicating that the controller
triggers the start of a new burst
sequence at or below the target