Command name
Access Length Address Bits
Description
UT_FAULT_RESPONSE
RW
Byte
54h
[7:0]
Instructs the device on what action to
take in response to an overtemperature
fault.
[7:6]: Response
0: Continue operation without
interruption
1: Continue operation for time specified
by delay bits [2:0] then if fault condition
still present, shut down and respond
according to retry bits [5:3]
2: Shut down and respond according to
retry bits [5:3]
3: Shut down until fault no longer
present
[5:3]: Retry setting
0: Remain disabled until fault cleared
1 to 6: Attempt to restart [5:3] times with
delay [2:0] between restarts
7: Attempt to restart continuously until
commanded OFF
[2:0]: Delay time
0 to 7: Number of delay time units
between restart attempts, unit defined
by FW_CONFIG_FAULTS command
VIN_OV_FAULT_LIMIT
RW
Word
55h
[15:0]
Sets the value of the input voltage that
causes an input overvoltage fault. The
format is LINEAR11. The hardware LSB is
0.125 V, suggesting an exponent of -3.
VIN_OV_FAULT_RESPONS
E
RW
Byte
56h
[7:0]
Instructs the device on what action to
take in response to an input overvoltage
fault.
[7:6]: Response
0: Continue operation without
interruption
1: Continue operation for time specified
by delay bits [2:0] then if fault condition
still present, shut down and respond
according to retry bits [5:3]
2: Shut down and respond according to
retry bits [5:3]
3: Shut down until fault no longer
present
[5:3]: Retry setting
0: Remain disabled until fault cleared
1 to 6: Attempt to restart [5:3] times with
delay [2:0] between restarts
7: Attempt to restart continuously until
commanded OFF
[2:0]: Delay time
0 to 7: Number of delay time units