![Infineon XDPP1100 Скачать руководство пользователя страница 192](http://html1.mh-extra.com/html/infineon/xdpp1100/xdpp1100_technical-reference-manual_2055193192.webp)
User Manual
192 of 562
V 1.0
2021-08-25
XDPP1100 technical reference manual
Digital power controller
Telemetry
tlm_vin_src_sel
Source
Comments
6
VRSEN
Non-pulsed/primary V
IN
sense via VSADC
7
BVRSEN
Non-pulsed/primary V
IN
sense via VSADC
When Loop 0 V
OUT
is selected as the V
IN
source for Loop 1, it is important to note that scaling by register
tlm1_vin_convert_factor
will apply. In order for this parameter to be computed correctly by the FW, Loop 1
(PMBus PAGE 1) commands should be programmed as follows:
•
PAGE 1 MFR_VRECT_SCALE = PAGE 0 (Loop 0) VOUT_SCALE_LOOP converted to LINEAR11 format
•
PAGE 1 MFR_TRANSFORMER_SCALE = B3FFh (0.999)
The selected input source is low-pass filtered at a programmable BW determined by register
tlmX_kfp_vin
. The
BW programming is shown in
. The output of the LPF is available as read-only register
tlmX_vin_lpf
. It
is used for the READ_VIN PMBus command as well as the V
IN
fault functions. The V
IN
telemetry submodule also
provides a 1/V
IN
output for use by the input CE.
Table 52
V
IN
, I
OUT
, I
IN
and duty-cycle LPF BW programming, where LSB = 0.0001221 and F
switch
= 1 MHz
tlm_kfp_vin
tlm_kfp_iout
tlm_kfp_iin
tlm_kfp_duty
kfp
kfp_real
F3db/F
switch
tlm_kfp_vin
tlm_kfp_iout
tlm_kfp_iin
tlm_kfp_duty
kfp
kfp_real
F3db/F
switch
0
4
0.0005
7.78E-05
20
128
0.0156
2.53E-03
1
5
0.0006
9.72E-05
21
160
0.0195
3.17E-03
2
6
0.0007
1.17E-04
22
192
0.0234
3.82E-03
3
7
0.0009
1.36E-04
23
224
0.0273
4.47E-03
4
8
0.0010
1.56E-04
24
256
0.0313
5.13E-03
5
10
0.0012
1.95E-04
25
320
0.0391
6.47E-03
6
12
0.0015
2.33E-04
26
384
0.0469
7.83E-03
7
14
0.0017
2.72E-04
27
448
0.0547
9.21E-03
8
16
0.0020
3.11E-04
28
512
0.0625
1.06E-02
9
20
0.0024
3.90E-04
29
640
0.0781
1.35E-02
10
24
0.0029
4.68E-04
30
768
0.0938
1.65E-02
11
28
0.0034
5.46E-04
31
896
0.1094
1.95E-02
12
32
0.0039
6.24E-04
32
1024
0.1250
2.27E-02
13
40
0.0049
7.81E-04
33
1280
0.1563
2.95E-02
14
48
0.0059
9.38E-04
34
1536
0.1875
3.67E-02
15
56
0.0068
1.10E-03
35
1792
0.2188
4.46E-02
16
64
0.0078
1.25E-03
36
2048
0.2500
5.31E-02
17
80
0.0098
1.57E-03
37
2560
0.3125
7.23E-02
18
96
0.0117
1.89E-03
38
3072
0.3750
9.55E-02
19
112
0.0137
2.21E-03
39
3584
0.4375
1.24E-01
Register
tlmX_vin_convert_factor
scales the VSADC formatted inputs for the transformer turns ratio and V
RECT
sense resistor divider and converts the binary point to 1 V. This register value is computed by FW based on