XDPP1100 technical reference manual
Digital power controller
Telemetry
8.14
PMBus
The relevant PMBus commands for telemetry are given in
Table 62
PWM-related PMBus commands
Command name
Access Length Address Bits
Description
VOUT_SCALE_LOOP
RW
Word
29h
[15:0]
Scales VOUT_COMMAND and other
V
OUT
-related commands for the
external resistor divider between V
OUT
and VSEN. The format is DIRECT, U0.16
and is computed as:
VOUT_SCALE_LOOP = INT(2^16 * VSEN
/ V
OUT
)
READ_VIN
R
Word
88h
[15:0]
Returns the measured input voltage in
volts in the LINEAR11 format with
exponent defined by
FW_CONFIG_TELEMETRY.READ_VIN_E
XP.
READ_IIN
R
Word
89h
[15:0]
Returns the measured input current in
amps in the LINEAR11 format with
exponent defined by
FW_CONFIG_TELEMETRY.READ_IIN_EX
P.
READ_VOUT
R
Word
8Bh
[15:0]
Returns the measured (not
commanded) output voltage in the
same format as set by the VOUT_MODE
command.
READ_IOUT
R
Word
8Ch
[15:0]
Returns the measured output current
in amps in the LINEAR11 format with
exponent defined by
FW_CONFIG_TELEMETRY.READ_IOUT_
EXP.
READ_TEMPERATURE_1
R
Word
8Dh
[15:0]
Returns the temperature at sensor 1 in
degrees Celsius in the LINEAR11
format. The temperature source for
sensor 1 is defined by
MFR_SELECT_TEMPERATURE_SENSOR
.Read_Temperature_1_Read_Tempera
ture_2_source_select.
READ_TEMPERATURE_2
R
Word
8Eh
[15:0]
Returns the temperature at sensor 2 in
degrees Celsius in the LINEAR11
format. The temperature source for
sensor 2 is defined by
MFR_SELECT_TEMPERATURE_SENSOR
.Read_Temperature_1_Read_Tempera
ture_2_source_select.
READ_DUTY_CYCLE
R
Word
94h
[15:0]
Returns the duty cycle in percent in the
LINEAR11 format with exponent
defined by