![Infineon XDPP1100 Скачать руководство пользователя страница 260](http://html1.mh-extra.com/html/infineon/xdpp1100/xdpp1100_technical-reference-manual_2055193260.webp)
User Manual
260 of 562
V 1.0
2021-08-25
XDPP1100 technical reference manual
Digital power controller
Fault handler
Peripheral Field name
Access Address
Bits
Description
3))
LSB = 125 mV, range = 0.0 to
127.875 V
fault
fault_vin_uv_warn_thre
sh
RW
7000_3C34h
(Loop 0)
7000_4034h
(Loop 1)
[9:0]
Input undervoltage warning
threshold.
Computed by FW from PMBus
command as follows:
fault_vin_uvp_warn_thresh =
Int(VIN_UV_WARN_LIMIT[10:0] *
2^(VIN_UV_WARN_LIMIT[15:11] +
3))
LSB = 125 mV, range = 0.0 to
127.875 V
fault
fault_iout_oc_fault_thre
sh
RW
7000_3C38h
(Loop 0)
7000_4038h
(Loop 1)
[9:0]
Output overcurrent fault threshold
Computed by FW from PMBus
command as follows:
fault_iout_oc_fault_thresh =
Int(IOUT_OC_FAULT_LIMIT[10:0] *
2^(IOUT_OC_FAULT_LIMIT[15:11]))
LSB = 1 A, range = 0 to 255 A
fault
fault_iout_oc_lv_fault_t
hresh
RW
7000_3C3Ch
(Loop 0)
7000_403Ch
(Loop 1)
[9:0]
Output overcurrent LV fault
threshold. Note that this threshold
is defined with respect to the
voltage at the VSEN pin, after the
V
OUT
sense resistor divider.
Computed by FW from PMBus
command as follows:
fault_iout_oc_lv_fault_thresh =
Int(IOUT_OC_LV_FAULT_LIMIT(U16
-X.X) * VOUT_SCALE_LOOP(U0.16) *
200 / (2^X * 2^16))
where X = negative of VOUT_MODE
exponent
LSB = 5 mV, range = 0.0 to 5.115 V
fault
fault_iout_oc_warn_thr
esh
RW
7000_3C40h
(Loop 0)
7000_4040h
(Loop 1)
[7:0]
Output overcurrent warn threshold.
Computed by FW from PMBus
command as follows:
fault_iout_oc_warn_thresh =
Int(IOUT_OC_WARN_LIMIT[10:0] *
2^IOUT_OC_WARN_LIMIT[15:11])
LSB = 1 A, range = 0 to 255 A
fault
fault_iout_uc_fault_thre
sh
RW
7000_3C44h
(Loop 0)
7000_4044h
(Loop 1)
[7:0]
Output undercurrent fault
threshold. Fault asserted when the
cycle-averaged output current is
below this threshold.
Computed by FW from PMBus
command as follows:
fault_iout_uc_fault_thresh =
Int(IOUT_UC_FAULT_LIMIT[10:0] *