![Infineon XDPP1100 Скачать руководство пользователя страница 63](http://html1.mh-extra.com/html/infineon/xdpp1100/xdpp1100_technical-reference-manual_2055193063.webp)
User Manual
63 of 562
V 1.0
2021-08-25
XDPP1100 technical reference manual
Digital power controller
Current sense (IS)
Peripheral Field name
Access Address
Bits
Description
4: V
RECT
(VRSEN/VRREF)
5: BV
RECT
(BVRSEN/BVRREF)
6: pid_ff_vrect_override
7: PRISEN
CE1 (BISEN):
0: V
RECT
(VRSEN/VRREF)
1: BV
RECT
(BVRSEN/BVRREF)
2: pid_ff_vrect_override
3: PRISEN
4: Loop 0 V
OUT
5: Loop 0 V
OUT
6: Loop 0 V
OUT
7: Loop 0 V
OUT
isen
ce_current_limit
RW
7000_2410h
(ISEN)
7000_2810h
(BISEN)
[26:18] Inductor PCL fault threshold in IADC
codes. The PWM pulse will be
truncated beyond this limit. Set to 0
to disable PCL fault protection.
ce_current_limit =
current_limit(amps) /
(MFR_IOUT_APC (amps/code))
LSB = 1 code, range = 0 to 511 codes
isen
ce_topology
RW
7000_2410h
(ISEN)
7000_2810h
(BISEN)
[28:27] Current emulator topology select.
Defines the inductor voltage
equations for V
ON
, V
OFF
.
0: Buck, ACF, HB, FB
1: Boost
2, 3: Buck-boost
isen
isp_fsw_sync_sel
RW
7000_2410h
(ISEN)
7000_2810h
(BISEN)
[29]
Defines which loop
’
s frequency is
used for averaging current over
switching cycle.
0: Loop 0 F
switch
1: Loop 1 F
switch
If ISEN is assigned to Loop 0 and
BISEN is assigned to Loop 1, then
set isen0.isp_fsw_sync_sel=0 and
isen1.isp_fsw_sync_sel=1. If both
ISEN and BISEN are assigned to
Loop 0, then set both parameters to
0.
isen
isp_track_fault_en
RW
7000_2414h
(ISEN)
7000_2814h
(BISEN)
[0]
Current sense tracking fault enable.
The tracking fault detects the
inability of the current sense
emulator to track the incoming
current sense signal. This fault is
typically an indication of board
problem (e.g., missing sense
resistor, bad pin conection).
0: Disabled
1: Enabled