XDPP1100 technical reference manual
Digital power controller
Fault handler
Peripheral Field name
Access Address
Bits
Description
12: IOUT_UC_FAULT
13: MFR_IOUT_OC_FAST
14: IIN_OC_FAULT
15: IIN_OC_WARN
16: OT_FAULT
17: OT_WARN
18: UT_FAULT
19: UT_WARN
20: POWER_LIMIT_MODE
21: ISHARE_FAULT
22: VOUT_MAX_MIN_WARN
23: SYNC_FAULT
24 to 31: Unused
fault
fault_reg_loop
R
7000_3C7Ch
(Loop 0)
7000_407Ch
(Loop 1)
[31:0]
Fault status register updated at
50 MHz. Once a fault bit is set it is
latched in this register and can only
be cleared via fault_clear_loop.
0: Reserved
1: VOUT_OV_FAULT
2: VOUT_OV_WARN
3: VOUT_UV_FAULT
4: VOUT_UV_WARN
5: VIN_OV_FAULT
6: VIN_OV_WARN
7: VIN_UV_FAULT
8: VIN_UV_WARN
9: IOUT_OC_FAULT
10: IOUT_OC_LV_FAULT
11: IOUT_OC_WARN
12: IOUT_UC_FAULT
13: MFR_IOUT_OC_FAST
14: IIN_OC_FAULT
15: IIN_OC_WARN
16: OT_FAULT
17: OT_WARN
18: UT_FAULT
19: UT_WARN
20: POWER_LIMIT_MODE
21: ISHARE_FAULT
22: VOUT_MAX_MIN_WARN
23: SYNC_FAULT
24 to 31: Unused
fault
fault_iout_cc_mode
R
7000_3C80h
(Loop 0)
7000_4080h
(Loop 1)
[0]
Status flag indicating I
OUT
constant
current mode operation.
0: Normal operation
1: Constant current mode