Telemetry
Peripheral Field name
Access Address
Bits
Description
telem
tlm_hilo_mark_A_sel
RW
7000_3448h
(Loop 0)
7000_3848h
(Loop 1)
[1:0]
Input select for high/low
watermark detector A.
0: V
IN
1: V
OUT
2: I
IN
3: I
OUT
telem
tlm_hilo_mark_B_sel
RW
7000_3448h
(Loop 0)
7000_3848h
(Loop 1)
[3:2]
Input select for high/low
watermark detector B.
0: V
IN
1: V
OUT
2: I
IN
3: I
OUT
telem
tlm_hilo_mark_A_clr
W
7000_344Ch
(Loop 0)
7000_384Ch
(Loop 1)
[0]
Clear for high/low watermark
detector A. Write first to 1 then to 0
to clear detector.
telem
tlm_hilo_mark_B_clr
W
7000_3450h
(Loop 0)
7000_3850h
(Loop 1)
[0]
Clear for high/low watermark
detector B. Write first to 1 then to 0
to clear detector.
telem
tlm_out_hi_A
R
7000_3454h
(Loop 0)
7000_3854h
(Loop 1)
[12:0]
High watermark detector A output.
Format depends on input selected
by tlm_hilo_mark_A_sel.
V
IN
: Unsigned, LSB = 62.5 mV, range
= 0.0 to 127.9375 V
V
OUT
: Unsigned, LSB = 1.25 mV,
range = 0.0 to 5.11875 V
I
IN
: Unsigned, LSB = 7.8125 mA,
range = 0.0 to 63.9922 A
I
OUT
: Signed, LSB = 62.5 mA, range =
-256 to +255.9375 A
telem
tlm_out_lo_A
R
7000_3454h
(Loop 0)
7000_3854h
(Loop 1)
[25:13] Low watermark detector A output.
Format depends on input selected
by tlm_hilo_mark_A_sel.
V
IN
: Unsigned, LSB = 62.5 mV, range
= 0.0 to 127.9375 V
V
OUT
: Unsigned, LSB = 1.25 mV,
range = 0.0 to 5.11875 V
I
IN
: Unsigned, LSB = 7.8125 mA,
range = 0.0 to 63.9922 A
I
OUT
: Signed, LSB = 62.5 mA, range =
-256 to +255.9375 A
telem
tlm_out_hi_B
R
7000_3458h
(Loop 0)
7000_3858h
(Loop 1)
[12:0]
High watermark detector B output.
Format depends on input selected
by tlm_hilo_mark_B_sel.
V
IN
: Unsigned, LSB = 62.5 mV, range
= 0.0 to 127.9375 V
V
OUT
: Unsigned, LSB = 1.25 mV,