![Infineon XDPP1100 Скачать руководство пользователя страница 280](http://html1.mh-extra.com/html/infineon/xdpp1100/xdpp1100_technical-reference-manual_2055193280.webp)
User Manual
280 of 562
V 1.0
2021-08-25
XDPP1100 technical reference manual
Digital power controller
Fault handler
Command name
Access Length Address Bits
Description
STATUS_TEMPERATURE
RW
Byte
7Dh
[7:0]
Returns one data byte with contents as
follows:
[7]: OT_FAULT
[6]: OT_WARNING
[5]: UT_WARNING
[4]: UT_FAULT
[3]: Reserved
[2]: Reserved
[1]: Reserved
[0]: Reserved
STATUS_CML
RW
Byte
7Eh
[7:0]
Returns one data byte with contents as
follows:
[7]: Invalid or unsupported command
received
[6]: Invalid or unsupported data received
[5]: Packet error check (PEC) failed
[4]: Memory fault detected
[3]: Processor fault detected
[2]: Reserved
[1]: A communication fault not listed has
occurred
[0]: Other memory or logic fault has
occurred
STATUS_OTHER
RW
Byte
7Fh
[7:0]
Returns one data byte with contents as
follows:
[7]: Reserved
[6]: Reserved
[5]: Reserved
[4]: Reserved
[3]: Reserved
[2]: Reserved
[1]: Reserved
[0]: First to assert SMBALERT#
STATUS_MFR_SPECIFIC
RW
Byte
80h
[7:0]
Returns one data byte with contents as
follows:
[7]: Sync fault
[6]: Reserved
[5]: IOUT_OC_FAST_FAULT
[4]: Common fault
[3]: External fault
[2]: Reserved
[1]: Reserved
[0]: Reserved
FW_CONFIG_FAULTS
RW
Block
25
Bytes
C8h
[1:0]
Temperature_Delay_Unit
: Time unit
for retry responses.
0: 1 ms
1: 4 ms
2: 16 ms
3: 256 ms