User Manual 402 of 562 V 1.0
2021-08-25
XDPP1100 technical reference manual
Digital power controller
Central processing unit subsystem
Register name Field name
Access Address
Bits
Description
INT_RAW
RAW_INSTR_DONE R
5002_0050h [1]
Raw (unmasked) instruction status.
0: OTP instruction not complete
1: OTP instruction complete
INT_RAW
RAW_READ_FAULT R
5002_0050h [2]
Raw (unmasked) READ fault status.
0: Fault did not occur during OTP
indirect reading
1: Fault occurred during OTP
indirect reading (timeout of
internally terminated READ)
INT_RAW
RAW_PROG_FAULT R
5002_0050h [3]
Raw (unmasked) PROG fault status.
0: Fault did not occur during OTP
programming
1: Fault occurred during OTP
programming
INT_MASK
MSK_PWR_STAT
RW
5002_0054h [0]
Mask for PWR_STAT.
0: Interrupt masked
1: Interrupt enabled
INT_MASK
MSK_INSTR_DONE RW
5002_0054h [1]
Mask for INSTR_DONE.
0: Interrupt masked
1: Interrupt enabled
INT_MASK
MSK_READ_FAULT RW
5002_0054h [2]
Mask for READ_FAULT.
0: Interrupt masked
1: Interrupt enabled
INT_MASK
MSK_PROG_FAULT RW
5002_0054h [3]
Mask for PROG_FAULT.
0: Interrupt masked
1: Interrupt enabled
INT_ACTIVE
PWR_STAT
R
5002_0058h [0]
Active (masked) power-up status.
0: OTP power-up not complete
1: OTP power-up complete
INT_ACTIVE
INSTR_DONE
R
5002_0058h [1]
Active (masked) instruction status.
0: OTP instruction not complete
1: OTP instruction complete
INT_ACTIVE
READ_FAULT
R
5002_0058h [2]
Active (masked) READ fault status.
0: Fault did not occur during OTP
indirect reading
1: Fault occurred during OTP
indirect reading (timeout of
internally terminated READ)
INT_ACTIVE
PROG_FAULT
R
5002_0058h [3]
Active (masked) PROG fault status.
0: Fault did not occur during OTP
programming
1: Fault occurred during OTP
programming