XDPP1100 technical reference manual
Digital power controller
Fault handler
Command name
Access Length Address Bits
Description
[14] I
OUT
/P
OUT
: An output current or
output power fault or warning has
occurred.
[13] INPUT: An input voltage, input
current or input power fault of warning
has occurred.
[12] MFRSPECIFIC: A manufacturer-
specific fault or warning has occurred.
[11] PG_STATUS: The POWER_GOOD
signal, if present, is negated.
[10] FANS: A fan fault or warning has
occurred.
[9] OTHER: A bit in STATUS_OTHER is
set.
[8] UNKNOWN: A fault or warning not
listed in bits [15:9] of STATUS_WORD has
occurred.
[7:0]: See STATUS_BYTE.
STATUS_VOUT
RW
Byte
7Ah
[7:0]
Returns one data byte with contents as
follows:
[7]: VOUT_OV_FAULT
[6]: VOUT_OV_WARNING
[5]: VOUT_UV_WARNING
[4]: VOUT_UV_FAULT
[3]: VOUT_MAX_MIN warning
[2]: TON_MAX_FAULT
[1]: TOFF_MAX_WARNING
[0]: Reserved
STATUS_IOUT
RW
Byte
7Bh
[7:0]
Returns one data byte with contents as
follows:
[7]: IOUT_OC_FAULT
[6]: IOUT_OC_LV_FAULT
[5]: IOUT_OC_WARNING
[4]: IOUT_UC_FAULT
[3]: Current sharing fault
[2]: In power limiting mode
[1]: Reserved
[0]: POUT_OP_WARNING
STATUS_INPUT
RW
Byte
7Ch
[7:0]
Returns one data byte with contents as
follows:
[7]: VIN_OV_FAULT
[6]: VIN_OV_WARNING
[5]: VIN_UV_WARNING
[4]: VIN_UV_FAULT
[3]: Unit off for insufficient voltage
[2]: IIN_OC_FAULT
[1]: IIN_OC_WARNING
[0]: PIN_OP_WARNING