![Infineon XDPP1100 Скачать руководство пользователя страница 234](http://html1.mh-extra.com/html/infineon/xdpp1100/xdpp1100_technical-reference-manual_2055193234.webp)
User Manual
234 of 562
V 1.0
2021-08-25
XDPP1100 technical reference manual
Digital power controller
Fault handler
referenced to VSEN and is computed by FW based on PMBus commands VOUT_OV_FAULT_LIMIT and
VOUT_SCALE_LOOP.
Output overvoltage warning
The output overvoltage warning is asserted when the VSP output in register
vspX_vout_fs
exceeds the warning
threshold (
fault_vout_ov_warn_thresh
) for the number of samples (
fault_vout_ov_warn_cnt
) without falling
below the threshold defined in Equation (9.2).
𝑡ℎ𝑟𝑒𝑠ℎ𝑜𝑙𝑑 = 𝑓𝑎𝑢𝑙𝑡_𝑣𝑜𝑢𝑡_𝑜𝑣_𝑤𝑎𝑟𝑛_𝑡ℎ𝑟𝑒𝑠ℎ − 𝑓𝑎𝑢𝑙𝑡_𝑣𝑜𝑢𝑡_𝑤𝑎𝑟𝑛_ℎ𝑦𝑠𝑡
(9.2)
The samples for the overvoltage warning definition do not need to be consecutive, but a single sample below
the value in Equation (9.2) will reset the count and deassert the warning. The register
fault_vout_ov_warn_thresh
is referenced to VSEN and is computed by FW based on PMBus commands
VOUT_OV_WARN_LIMIT and VOUT_SCALE_LOOP.
Output undervoltage fault
The output undervoltage fault is asserted when the VSP output in register
vspX_vout_fs
falls below the fault
threshold (
fault_vout_uv_fault_thresh
) for the number of samples (
fault_vout_uv_fault_cnt
) without
exceeding the threshold defined in Equation (9.3).
𝑡ℎ𝑟𝑒𝑠ℎ𝑜𝑙𝑑 = 𝑓𝑎𝑢𝑙𝑡_𝑣𝑜𝑢𝑡_𝑢𝑣_𝑓𝑎𝑢𝑙𝑡_𝑡ℎ𝑟𝑒𝑠ℎ + 𝑓𝑎𝑢𝑙𝑡_𝑣𝑜𝑢𝑡_𝑓𝑎𝑢𝑙𝑡_ℎ𝑦𝑠𝑡
(9.3)
The samples for the undervoltage definition do not need to be consecutive but a single sample above the value
in Equation (9.3) will reset the count and deassert the fault. The register
fault_vout_uv_fault_thresh
is
referenced to VSEN and is computed by FW based on PMBus commands VOUT_UV_FAULT_LIMIT and
VOUT_SCALE_LOOP.
Output undervoltage warning
The output undervoltage warning is asserted when the VSP output in register
vspX_vout_fs
falls below the
warning threshold (
fault_vout_uv_warn_thresh
) for the number of samples (
fault_vout_uv_warn_cnt
)
without exceeding the threshold defined in Equation (9.4).
𝑡ℎ𝑟𝑒𝑠ℎ𝑜𝑙𝑑 = 𝑓𝑎𝑢𝑙𝑡_𝑣𝑜𝑢𝑡_𝑢𝑣_𝑤𝑎𝑟𝑛_𝑡ℎ𝑟𝑒𝑠ℎ + 𝑓𝑎𝑢𝑙𝑡_𝑣𝑜𝑢𝑡_𝑓𝑎𝑢𝑙𝑡_ℎ𝑦𝑠𝑡
(9.4)
The samples for the undervoltage warning do not need to be consecutive but a single sample above the value
in Equation (9.4) will reset the count and deassert the warning. The register
fault_vout_uv_warn_thresh
is
referenced to VSEN and is computed by FW based on PMBus commands VOUT_UV_WARN_LIMIT and
VOUT_SCALE_LOOP.
Output voltage fault-related PMBus commands
The output voltage faults and warnings are reported on the following PMBus commands:
•
STATUS_BYTE
•
STATUS_WORD
•
STATUS_VOUT
It should be noted that VOUT_OV_FAULT and VOUT_UV_FAULT remain asserted in the PMBus STATUS
command until VOUT_OV_WARNING and VOUT_UV_WARNING are deasserted. The XDPP1100 response to the
output voltage faults is programmed through the PMBus commands:
•
VOUT_OV_FAULT_RESPONSE
•
VOUT_UV_FAULT_RESPONSE