![Infineon XDPP1100 Скачать руководство пользователя страница 258](http://html1.mh-extra.com/html/infineon/xdpp1100/xdpp1100_technical-reference-manual_2055193258.webp)
User Manual
258 of 562
V 1.0
2021-08-25
XDPP1100 technical reference manual
Digital power controller
Fault handler
Peripheral Field name
Access Address
Bits
Description
7: VIN_UV_FAULT
8: VIN_UV_WARN
9: IOUT_OC_FAULT
10: IOUT_OC_LV_FAULT
11: IOUT_OC_WARN
12: IOUT_UC_FAULT
13: MFR_IOUT_OC_FAST
14: IIN_OC_FAULT
15: IIN_OC_WARN
16: OT_FAULT
17: OT_WARN
18: UT_FAULT
19: UT_WARN
20: POWER_LIMIT_MODE
21: ISHARE_FAULT
22: VOUT_MAX_MIN_WARN
23: SYNC_FAULT
24 to 31: Unused
fault
fault_vout_ov_fault_thr
esh
RW
7000_3C18h
(Loop 0)
7000_4018h
(Loop 1)
[9:0]
Output overvoltage fault threshold.
Note that this threshold is defined
with respect to the voltage at the
VSEN pin, after the V
OUT
sense
resistor divider.
Computed by FW from PMBus
command as follows:
fault_vout_ovp_fault_thresh =
Int(VOUT_OV_FAULT_LIMIT(U16-
X.X) * VOUT_SCALE_LOOP(U0.16) *
200 / (2^X * 2^16))
where X = negative of VOUT_MODE
exponent
LSB = 5 mV, range = 0.0 to 5.115 V
fault
fault_vout_ov_warn_thr
esh
RW
7000_3C1Ch
(Loop 0)
7000_401Ch
(Loop 1)
[9:0]
Output overvoltage warning
threshold. Note that this threshold
is defined with respect to the
voltage at the VSEN pin, after the
V
OUT
sense resistor divider.
Computed by FW from PMBus
command as follows:
fault_vout_ovp_warn_thresh =
Int(VOUT_OV_WARN_LIMIT(U16-
X.X) * VOUT_SCALE_LOOP(U0.16) *
200 / (2^X * 2^16))
where X = negative of VOUT_MODE
exponent
LSB = 5 mV, range = 0.0 to 5.115 V
fault
fault_vout_uv_fault_thr
esh
RW
7000_3C20h
(Loop 0)
7000_4020h
(Loop 1)
[9:0]
Output undervoltage fault
threshold. Note that this threshold
is defined with respect to the
voltage at the VSEN pin, after the