![Infineon XDPP1100 Скачать руководство пользователя страница 401](http://html1.mh-extra.com/html/infineon/xdpp1100/xdpp1100_technical-reference-manual_2055193401.webp)
User Manual 401 of 562 V 1.0
2021-08-25
XDPP1100 technical reference manual
Digital power controller
Central processing unit subsystem
Register name Field name
Access Address
Bits
Description
DATAW3
DATA
RW
5002_001Ch [31:0]
DATA[127:96] written to OTP by
PROG and PROG+Verify
instructions.
READ_MRAB
MRB_READ
RW
5002_0020h [15:0]
MRB register setting to be used for
OTP READ.
READ_MRAB
MRA_READ
RW
5002_0020h [31:16] MRA register setting to be used for
OTP READ.
READ_MR
MR_READ
RW
5002_0024h [15:0]
MR register setting to be used for
OTP READ.
READ1_MRAB
MRB_READ1
RW
5002_0028h [31:16] MRB register setting to be used for
OTP READ1 during OTP
programming.
READ1_MRAB
MRA_READ1
RW
5002_0028h [15:0]
MRA register setting to be used for
OTP READ1 during OTP
programming.
READ1_MR
MR_READ1
RW
5002_002Ch [31:16] MR register setting to be used for
OTP READ1 during OTP
programming.
READ2_MRAB
MRB_READ2
RW
5002_0030h [15:0]
MRB register setting to be used for
OTP READ2 during OTP
programming.
READ2_MRAB
MRA_READ2
RW
5002_0030h [31:16] MRA register setting to be used for
OTP READ2 during OTP
programming.
READ2_MR
MR_READ2
RW
5002_0034h [15:0]
MR register setting to be used for
OTP READ2 during OTP
programming.
OPT_MRAB
OTP_MRA
R
5002_0038h [31:16] MRA register output from OTP
(current configuration).
OPT_MRAB
OTP_MRB
R
5002_0038h [15:0]
MRB register output from OTP
(current configuration).
OPT_MR
OTP_MR
R
5002_003Ch [31:16] MR register output from OTP
(current configuration).
OTP_Q0
DATA
R
5002_0040h [31:0]
DATA[31:0] output of OTP macro
(used for READ).
OTP_Q1
DATA
R
5002_0044h [31:0]
DATA[63:2] output of OTP macro
(used for READ).
OTP_Q2
DATA
R
5002_0048h [31:0]
DATA[95:64] output of OTP macro
(used for READ).
OTP_Q3
DATA
R
5002_004Ch [31:0]
DATA[127:96] output of OTP macro
(used for READ).
INT_RAW
PWR_STAT
R
5002_0050h [0]
Raw (unmasked) power-up status.
0: OTP power-up not complete
1: OTP power-up complete