7-16
PILOT PRIMARY PRESSURE
Preparation
Keep the hydraulic oil temperature at
50
Ü
5˚C.
Measurement
Select the following switch positions.
Power mode switch : P mode
Auto decel switch
: OFF
Measure the primary pilot pressure by
the monitoring menu of the cluster.
Evaluation
13)
(1)
(2)
Η
Â
Â
Θ
Η
The average measured pressure should meet the following specifications:
Unit : kgf / cm
2
a3
Coupling
Main pump
Monitoring
(analog)
Cluster
(3)
Model
HX145CR
HX145LCR
Engine speed
P mode
Standard
40
Allowable limits
-
Remarks
145ZF7MS12
+2
0
Содержание HX145 LCR