6-32
9. WHEN FUEL GAUGE DOES NOT OPERATE
9. WHEN FUEL GAUGE DOES NOT OPERATE (HCESPN 301, FMI 3 or 4)
·
Before disconnecting the connector, always turn the starting switch OFF.
·
Before carrying out below procedure, check all the related connectors are properly inserted.
·
After checking, insert the disconnected connectors again immediately unless otherwise specified.
CN-51
MCU
5
CN-52
26
CD-2
2
1
FUEL LEVEL SENDER
Cause
Remedy
Defective MCU or
cluster
Disconnection in
wiring harness or
poor contact
between fuel
sender-MCU
Defective fuel
sender
Replace
Repair or replace
Replace
YES
YES
Starting switch : OFF
Spec : 50~600
Ω
See table
Check resistance
between fuel
sender (1) and
(2)
Check resistance
between CN-51
(5) and CN-52
(26)
Starting switch : OFF
Disconnect CN-51, CN-52
Spec : 50~600
Ω
NO
NO
300L6ES10
Check Table
Check Table
Range
Resistance (
Ω
)
Range
Resistance (
Ω
)
Full
50
5/12
400
11/12
100
4/12
450
10/12
150
3/12
500
9/12
200
2/12
550
8/12
250
1/12
600
7/12
300
Empty warning
700
6/12
350
-
-
Содержание HX145 LCR
Страница 11: ...SECTION 1 GENERAL SECTION 1 GENERAL Group 1 Safety Hints 1 1 Group 2 Specifications 1 10...
Страница 204: ...4 5 MEMORANDUM HYUNDAI HEAVY INDUSTRIES CO LTD CONSTRUCTION EQUIPMENT DIV...
Страница 553: ...8 82 Insert O rings to the relief valve 30 and reassemble them to rear cover 20 This completes assembly 17 32038SM42...
Страница 627: ...8 155 125LCR8TM30 Turn casing 1 upside down and remove oil seal 3 using jig 29...
Страница 636: ...8 164 125LCR8TM61 After assembling spring 44 in order clamp plug 41 Tightening torque 5 kgf m 36 lbf ft 31...
Страница 657: ...8 185 8 185 Remove lock nut 22 and then boot 23 14 36078RL14 2507ARL10...
Страница 668: ...8 196 14 15 3 Install cover 3 to body 1 and tighten bolts 14 Torque 10 12 5 kgf m 72 3 90 4 lbf ft 7 21078DA10...