2-13
Total horsepower control
The regulator decreases the pump tilting
angle (delivery flow) automatically to limit
the input torque within a certain value with
a rise in the delivery pressure P1 of the
self pump and the delivery pressure P2 of
the companion pump.
(The input horsepower is constant when
the speed is constant.)
Since the regulator is of the simultaneous
total horsepower type that operates by the
sum of load pressures of the two pumps
in the tandem double-pump system, the
prime mover is automatically prevented
from being overloaded, irrespective of the
load condition of the two pumps, when
horsepower control is under way.
Since this regulator is of the simultaneous
total horsepower type, it controls the tilting
angles (displacement volumes) of the two
pumps to the same value as represented
by the following equation :
Tin = P1
Ý
q/2
ӕ
+ P2
Ý
q/2
ӕ
= (P1+P2)
Ý
q/2
ӕ
The horsepower control function is the
same as the flow control function and is
summarized in the following. (For detailed
behaviors of respective parts, refer to the
section of flow control).
(2)
Delivery pressure, (P
1
+P
2
)
Deliv
er
y flo
w
, Q
Содержание HX145 LCR
Страница 11: ...SECTION 1 GENERAL SECTION 1 GENERAL Group 1 Safety Hints 1 1 Group 2 Specifications 1 10...
Страница 204: ...4 5 MEMORANDUM HYUNDAI HEAVY INDUSTRIES CO LTD CONSTRUCTION EQUIPMENT DIV...
Страница 553: ...8 82 Insert O rings to the relief valve 30 and reassemble them to rear cover 20 This completes assembly 17 32038SM42...
Страница 627: ...8 155 125LCR8TM30 Turn casing 1 upside down and remove oil seal 3 using jig 29...
Страница 636: ...8 164 125LCR8TM61 After assembling spring 44 in order clamp plug 41 Tightening torque 5 kgf m 36 lbf ft 31...
Страница 657: ...8 185 8 185 Remove lock nut 22 and then boot 23 14 36078RL14 2507ARL10...
Страница 668: ...8 196 14 15 3 Install cover 3 to body 1 and tighten bolts 14 Torque 10 12 5 kgf m 72 3 90 4 lbf ft 7 21078DA10...