Part name
Symbol
Specifications
Check
Start relay
24V 300A
侍#
Check contact
Normal : 0.94
̫
(for terminal 1-2)
Blower motor
24V 14A
侍#
Check resistance
Normal : 2.5
̫
(for terminal 1-2)
Air conditioner
duct sensor
(switch)
1˚C OFF
4˚C ON
侍#
Check resistance
Normal : 0
̫
(for terminal 1-2),
the atmosphere temp :
Over 4˚C
Door switch
24V 2W
侍#
Check resistance
Normal : About 5M
̫
Switch
(power max,
one touch
decel, horn,
breaker)
24V 6A
侍#
Check resistance
Normal :
â̫
Circuit breaker
CN-60 : 60A
CN-95 : 90A
侍#
Check disconnection
Normal : 0
̫
(connect ring terminal and check
resist between terminal 1 and 2)
4-28
M
1
2
1
2
CS-1
1
2
CS-5 CS-19
CS-26 CS-29
CR-23
2
1
CN60
CN-95
2
1