6-66
TEST PROCEDURE
TEST PROCEDURE
Test 18
Test 18: Check voltage between connector
CN-88 (2) - GND.
Disconnect connector CN-88 from power
max solenoid valve.
Start switch ON.
Check voltage as figure.
(1)
(1)
①
②
③
2)
2)
Test 19
Test 19: Check resistance of the solenoid
valve between CN-88 (1)-(2).
Starting switch OFF.
Disconnect connector CN-88 from power
max solenoid valve.
Check resistance as figure.
(2)
(2)
①
②
③
LH RCV-lever
Power max switch
Power max
solenoid valve
CN-88
Multimeter
1
2
1
2
21096MS14B
LH RCV-lever
Power max switch
Power max
solenoid valve
CN-88
Multimeter
1
2
1
2
GROUND
SPEC : Starting switch ON : 24
±
1V
Starting switch OFF : 0V
SPEC : 15~35
Ω
21096MS14A