5-40
DTC
Diagnostic Criteria
Application
HCESPN FMI
G
C
W
866
2
(When mounting the AAVM)
60 seconds continuous, AAVM communication Data Error
侑
(Results / Symptoms)
1. Control Function – AAVM operation failure
(Checking list)
1. CN-401 (#86) – CN-51 (#22) Checking Open/Short
2. CN-401 (#87) – CN-51 (#32) Checking Open/Short
867
2
60 seconds continuous, RDU communication Data Error
侑
(Results / Symptoms)
1. Control Function – RDU operation failure
(Checking list)
1. CN-376 (#10) – CN-51 (#22) Checking Open/Short
2. CN-376 (#18) – CN-51 (#32) Checking Open/Short
868
2
60 seconds continuous, Switch Controller communication Data Error
侑
(Results / Symptoms)
1. Control Function – Switch Controller operation failure
(Checking list)
1. CN-56A (#7) – CN-51 (#22) Checking Open/Short
2. CN-56A (#6) – CN-51 (#32) Checking Open/Short
869
2
(When mounting the BKCU)
60 seconds continuous, BKCU communication Data Error
侑
(Results / Symptoms)
1. Control Function – BKCU operation failure
(Checking list)
1. CS-2B (#A) – CN-51 (#22) Checking Open/Short
2. CS-2B (#B) – CN-51 (#32) Checking Open/Short
G : General C : Crawler Type W : Wheel Type
侍#
Some error codes are not applied to this machine.
Содержание HX145 LCR
Страница 11: ...SECTION 1 GENERAL SECTION 1 GENERAL Group 1 Safety Hints 1 1 Group 2 Specifications 1 10...
Страница 204: ...4 5 MEMORANDUM HYUNDAI HEAVY INDUSTRIES CO LTD CONSTRUCTION EQUIPMENT DIV...
Страница 553: ...8 82 Insert O rings to the relief valve 30 and reassemble them to rear cover 20 This completes assembly 17 32038SM42...
Страница 627: ...8 155 125LCR8TM30 Turn casing 1 upside down and remove oil seal 3 using jig 29...
Страница 636: ...8 164 125LCR8TM61 After assembling spring 44 in order clamp plug 41 Tightening torque 5 kgf m 36 lbf ft 31...
Страница 657: ...8 185 8 185 Remove lock nut 22 and then boot 23 14 36078RL14 2507ARL10...
Страница 668: ...8 196 14 15 3 Install cover 3 to body 1 and tighten bolts 14 Torque 10 12 5 kgf m 72 3 90 4 lbf ft 7 21078DA10...