5-79
Auto power boost
刱
The power boost function can be activated or cancelled.
Enable - The digging power is automatically increased as working conditions by the MCU.
It is operated max 8 seconds.
Disable - Not operated.
余
290F3CD117
210WF3CD118
LSF#prgh
刲
The IPC mode can be selected by this menu.
- Speed mode
- Balance mode (default)
- Effi ciency mode
This mode is applied only general operation mode of the work tool mode.
Please update the cluster programs if this mode is not displayed in the mode setup menu. Refer
to the operator's manual page 3-25-1.
余
余
侍
290F3CD310
290F3CD311
290F3CD312
290F3CD313
290F3CD304
290F3CD305
290F3CD306