6-7
Oil cooler clogged.
Bypass check
valve is defective.
ⓐ
Replenish
specified oil to
the standard
level.
Clean oil cooler.
Replace
Adjust belt
tension or
replace belt.
Readjust set
pressure.
Reduce load.
YES
NO
Is hydraulic oil
volume proper?
Is oil cooler clogged
and is bypass check
valve always open?
Is main relief
valve used very
often?
Is not the set
pressure of main
relief, port relief
and travel relief
valve lower than
the standard
level?
Is fan belt
tension proper?
ⓐ
YES
NO
YES
YES
YES
YES
NO
NO
NO
Drop hydraulic oil
sample on hot
plate and check if
foams come up.
Water is mixed.
Air is intruded.
Put hydraulic oil
still, separate
water and
dispose it or
replace hydraulic
oil.
Check suction
line and return
line and eliminate
the air intruding
source.
3. HYDRAULIC SYSTEM
3. HYDRAULIC SYSTEM
HYDRAULIC OIL IS CLOUDY
HYDRAULIC OIL IS CLOUDY
1)
1)
HYDRAULIC OIL TEMPERATURE HAS RISEN ABNORMALLY
HYDRAULIC OIL TEMPERATURE HAS RISEN ABNORMALLY
2)
2)
Cause
Remedy
Cause
Remedy
Содержание HX145 LCR
Страница 11: ...SECTION 1 GENERAL SECTION 1 GENERAL Group 1 Safety Hints 1 1 Group 2 Specifications 1 10...
Страница 204: ...4 5 MEMORANDUM HYUNDAI HEAVY INDUSTRIES CO LTD CONSTRUCTION EQUIPMENT DIV...
Страница 553: ...8 82 Insert O rings to the relief valve 30 and reassemble them to rear cover 20 This completes assembly 17 32038SM42...
Страница 627: ...8 155 125LCR8TM30 Turn casing 1 upside down and remove oil seal 3 using jig 29...
Страница 636: ...8 164 125LCR8TM61 After assembling spring 44 in order clamp plug 41 Tightening torque 5 kgf m 36 lbf ft 31...
Страница 657: ...8 185 8 185 Remove lock nut 22 and then boot 23 14 36078RL14 2507ARL10...
Страница 668: ...8 196 14 15 3 Install cover 3 to body 1 and tighten bolts 14 Torque 10 12 5 kgf m 72 3 90 4 lbf ft 7 21078DA10...