Section 11 — WaveSample and Layer Parameters
Edit/Env 1, Env 2, Env 3 Parameters
15
EDIT
ENVELOPE MODE
ENV
Press Edit / Env1, Env2, or Env3 / 8
ENVELOPE MODE has three states:
• NORMAL: as pictured in the previous envelope diagrams.
• FINISH: envelope runs its full cycle, ignoring the key-up event.
• REPEAT: In this mode, the envelope will run through levels 2 through 5, using times 1
through 4, repeatedly as long as the key is down.
EDIT
ENVELOPE (Envelope Template)
ENV
Press Edit / Env1, Env2, or Env3 / 0
The last parameter on the Envelope page usually reads ENVELOPE=CURRENT VALUE. This is
the envelope template parameter.
There are a number of “typical” envelope templates permanently stored in the ASR-10; they each
have a name. When you select one of these envelopes, its twenty-one parameters are copied into
the envelope of the WaveSample or WaveSamples you are editing. The old values are
temporarily saved as the CURRENT VALUE. You can go back to CURRENT VALUE any time
you wish, unless you change any of the values in one of the template envelopes. Editing
individual parameters of any envelope causes it to become the CURRENT VALUE of that
particular envelope.
The following diagram illustrates the 14 typical envelope templates.