6 Commissioning
TopClean S CPC 30
64
EHauser
Cleaning programmes
The programmes can be triggered automatically at preset intervals, manually or in the
event of an error message. Almost any error message can be programmed to start a
programme.
For electrical connection of the binary coding for an external programme start, please
refer to the table "Terminal assignment CPC 30" (s. page 17).
What is sealing water?*
In processes with fibrous or adhesive media, assemblies with ball valves are fitted to
block the medium, e.g. ProbFit CPA 463 or CleanFit P CPA 477. To keep the rinse
chamber free of medium, the sealing water valve opens automatically before the
assembly emerges from the process. The counterpressure in the rinse chamber caused
by the sealing water prevents the ingress of medium into the chamber. The sealing
water pressure must then be greater than the pressure of the medium. Sealing water is
conveyed one second before the assembly moves to the maintenance position.
No.
Function
→
Programme
↓
Cleaning
Sterilisation
Sealing
water*
Binary Coding
bin. 0
bin. 1
bin. 2
Kl. 81/82 Kl. 83/84 Kl. 85/86
1
Clean
(= cleaning)
✓
–
Control for
1 valve
required
1
0
0
2
Clean S
(= cl
sterilisation)
✓
Control for
1 valve
required
–
0
0
1
3
Clean Int
(= cleaning
interval)
✓
–
Control for
1 valve
required
Programme cannot be
started externally.
4
User 1
✓
The external additional valve
can be used as required, e.g. for
superheated steam, organic
cleaner, 2nd cleaner, cooling
air.
Device control for 1 valve is
required.
1
0
1
5
User 2
✓
0
1
1
6
User 3
✓
1
1
1