11 Appendix
TopClean S CPC 30
124
EHauser
PARAM
Editing service code
0000
(0...9997)
Editing specialist
code
0000
(0...9997)
C07-CPC30xxx-19-06-08-en-006.EPS
Editing Damping
pH/ORP:
00s
Temperature:
00s
Display format
pH 00.00
pH 00.0
(only pH)
Select temperature
display
°C
° F
Select
Current output conf.
Current output 1
2
Current output
Relay function
Acc. NAMUR off
Relay 1:
free
Relay 2:
free
Select
Current output 1/2
pH/mV Input 1
pH/mV Input 2
Temperature Input 1
Temperature Input 2
Delta Input 2-1
Select NAMUR
NC contact
NO contact
Select Limit
NC contact
NO contact
Note if selection is
changed:
Caution! Conf. will
be reset.
(Cancel with
PARAM)
Select Controller
NC contact
NO contact
Select Failure
configuration
Active on
Active pulse
Note field
Chemoclean is
always NO.
(if CCC and CCW
selected)
Select
Output range 1/2
0 … 20 mA
4 … 20 mA
Warning if
»Min« is selected
for current range
0...20mA
Select characteristic
1/2
linear
table
Edit number
0/4 mA: 02.00pH
(000.0°C)
20 mA: 12.00pH
(100.0°C)
Info field
Current output 1/2
linear active
Edit table points
pH mA
00.00 04.00
(000.0°C)
Enter number
of table points
01
(1...10)
Select
Temp.comp. sensor
Temp.comp.
process (only pH)
Select temp. comp.
ATC Input 1
ATC Input 2
MTC
MTC + Temp.
(only pH)
Edit MTC temp.
025.0°C
(only pH,MTC)
(-20.0...150.0°C)
Temperature
measurement
off
on
(only Redox)
Temp.sensor
Pt 100
Pt 1000
NTC 30k
Actual temp. value
for Offset
25.0°C
(20.0...30.0°C)
Edit Offset
0.0°C
(-5.0...5.0°C)
Select
Select table
Create table
Reference
temperature
Select medium K1
Medium 1
Medium 2
Medium 3
no
Select medium
Medium 1
Medium 2
Medium 3
Reference
temperature in
laboratory meas.
25.0°C
(-20.0...150.0°C)
Select
Sensor input
Display
Bus configuration
Access codes
Current output
Relays
Temperature
(Alarm,
Hold,
Calibration see below)
Select operating
mode
pH
Redox/ORP: mV
Redox/ORP: %
Editing tag number
(0...9; A...Z)
Select electrode
type 1
Glass electrode 7.0
Glass electrode 4.6
Antimony
IsFET
(only pH)
Select
Sensor ground
solution ground
no solution ground
Date+time
Weekday Mo
Day 30
Month 04
Year 01
Time 12:00
Editing Contrast
with + and - keys
Select language
English GB
Deutsch D
Spanish ESP
Francais F
Italian I
»Return field«:
press the PARAM
key to return to
these highlighted
fields.
= Code entry required
Back to
return field
Back to
return field
Edit pairs
°C pH
000.0 00.00
Query
Ok
Delete pair
(then back to the
edit pairs)
Note field
Table status
invalid table
--> back
Valid table
--> to return field
Edit table points
00
(2...10)
Back to
return field
Back to
return field
PARAM
Set up 2
Controller values
Manual Operation
First Set up
Set up 1
Entry of
bus address
0
(0...15)
(only communication)
Display of meas.
point designation
(tag number)
- - - - - - - -
(only communication)