8 Trouble-shooting
Hauser
109
8.4.2
Coding
Current outputs active or passive:
in the device versions CPM 153-xxxA/-xxxB (2 current outputs) the current outputs can
be operated as either active or passive. Jumpers on the controller module M3CH allow
recoding.
For non-Ex systems, these modules may be recoded to active outputs.
8.5
CPG 30 Spare parts
For your own safety, always use genuine spare parts. Only genuine spare parts ensure
correct functioning, accuracy and reliability after corrective maintenance.
You receive all spare parts in the form with a unique code, optimally adapted packaging
including ESD protection for modules and a set of instructions.
Fig. 32: Coding of the current outputs
(Interior view of the CPM 153 housing upper section)
Fig. 33: Active/passive coding of the current
outputs
1
2
C07-CPM153xx-09-06-00-xx-001.EPS
1
2
1
1
1
1
2
1
Jumper setting
passive output
Jumper setting
active output
C07-CPM153xx-09-06-00-en-002.EPS