manualshive.com logo in svg
background image

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

KH20 

Krypton 

Hygrometer 

 

  
 
 
 

User Manual 

 
 
 
 
 

 
 
 

 
 
 

  Issued  23.3.10

 

 
 
 
 
 
 
 

 
 
 
   

Copyright 

©

 2010 Campbell Scientific Inc. 

  Printed under Licence by Campbell Scientific Ltd. 

 
 

 

CSL 876 

Содержание KH20

Страница 1: ...KH20 Krypton Hygrometer User Manual Issued 23 3 10 Copyright 2010 Campbell Scientific Inc Printed under Licence by Campbell Scientific Ltd CSL 876...

Страница 2: ......

Страница 3: ...lieu of all other guarantees expressed or implied including those of suitability and fitness for a particular purpose Campbell Scientific is not liable for consequential damage Please inform us befor...

Страница 4: ......

Страница 5: ...l cell phones and aerials may also not be applicable according to your locality Some brackets shields and enclosure options including wiring are not sold as standard items in the European market in so...

Страница 6: ......

Страница 7: ...tronics Box 3 4 Wiring 5 5 Datalogger Programming 6 5 1 KH20 Calibration 6 5 2 Example 1 CR3000 Program to Measure Water Vapour Fluctuations 7 6 Maintenance and Calibration 8 6 1 Visual Inspection 9 6...

Страница 8: ...i Tables 1 Datalogger Connections for Differential Measurement 5 2 KH20 Calibration Ranges 6 A 1 Linear Regression Results for KH20 ln mV vs Vapour Density A 2 A 2 Final Calibration Values for KH20 A...

Страница 9: ...he connectors are housed inside a rain shield 14113 that protects them from moisture The KH20 is suitable for long term continuous outdoor applications The KH20 sensor is comprised of two main parts t...

Страница 10: ...aded aluminium pipe 3874 Nu rail 3 4 x 3 4 1017 Allen Wrench 5 32 4697 3 Installation 3 1 Siting When installing the KH20 sensor for latent heat flux measurement in an eddy covariance application prop...

Страница 11: ...bottom front of the rain shield and then pushing the cover all the way up and sliding it out It will be difficult to mount the rain shield to a mast with the front cover on since the 1 2 inch nut hol...

Страница 12: ...ll block the position of the connectors 3 Mount the rain shield onto the tripod or tower mast using the U bolt provided Make sure that the distance between the KH20 sensor head and the rain shield is...

Страница 13: ...e two pan head screws to secure it in place 6 Gather any loose cables and tie them up using cable ties onto the tripod or tower mast 4 Wiring The KH20 sensor is shipped with a power signal cable with...

Страница 14: ...cients are calculated See Appendix A for more information on KH20 calibration Table 2 KH20 Calibration Ranges Ranges Vapour Density g m3 Full Vapour Range 2 19 Dry Vapour Range 2 9 5 Wet Vapour Range...

Страница 15: ...opriate values found from the calibration sheet of the KH20 Unit Definitions Units Units ln_mV ln mV natural log of the KH20 millivolts mV millivolts rho_w g m 3 Wiring ANALOG INPUT 1H KH20 signal whi...

Страница 16: ...temp 250 Measure battery voltage Battery batt_volt Measure KH20 VoltDiff kh_mV 1 mV5000 1 TRUE 200 250 1 0 ln_kh LOG kh_mV rho_w ln_kh xkw CallTable stats CallTable ts_data NextScan EndProg 6 Maintena...

Страница 17: ...ut reading is below 50 mV you may have problems with either the source tube or the detector tube For the detector tube testing see Section 6 3 below 6 3 Testing the Detector Tube If the source tube te...

Страница 18: ...ean the scaled window After cleaning the window slide a clean dry swab across the window to confirm the scale has been removed You can use the water vapour absorption coefficient for scaled window fro...

Страница 19: ...length for the KH20 sensor and w is the water vapour density w wx k e T A 1 If we express the transmissivity T in terms of the light intensity before and after passing through the material as measure...

Страница 20: ...xkw 0 205 Y Intercept ln V0 8 033 If we substitute these values along with the measured lnV into equation A 3 we can obtain the water vapour density w Campbell Scientific Inc performs the calibration...

Страница 21: ...20 A 3 Table A 2 Final Calibration Values for KH20 Vapour Range g m3 Slope xkw Y Intercept ln V0 Coefficient kw Full Range 1 74 19 25 0 205 3087 0 144 Dry Range 1 74 9 20 0 216 3259 0 151 Wet Range 7...

Страница 22: ...CANADA www campbellsci ca dataloggers campbellsci ca Campbell Scientific Centro Caribe S A CSCC 300N Cementerio Edificio Breller Santo Domingo Heredia 40305 COSTA RICA www campbellsci cc info campbell...