Campbell EE181 Скачать руководство пользователя страница 1

INST
RUCT

IO

N

 MANUAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EE181 Temperature 

and Relative Humidity Probe 

Revision: 3/17 

C o p y r i g h t   ©   2 0 1 6 - 2 0 1 7  

C a m p b e l l   S c i e n t i f i c ,   I n c .  

Содержание EE181

Страница 1: ...INSTRUCTION MANUAL EE181 Temperature and Relative Humidity Probe Revision 3 17 C o p y r i g h t 2 0 1 6 2 0 1 7 C a m p b e l l S c i e n t i f i c I n c...

Страница 2: ......

Страница 3: ...ucts to CSI CSI will return such Products by surface carrier prepaid within the continental United States of America To all other locations CSI will return such Products best way CIP port of entry per...

Страница 4: ...address is CAMPBELL SCIENTIFIC INC RMA _____ 815 West 1800 North Logan Utah 84321 1784 For all returns the customer must fill out a Statement of Product Cleanliness and Decontamination form and comply...

Страница 5: ...beginning work Wear a hardhat and eye protection and take other appropriate safety precautions while working on or around tripods and towers Do not climb tripods or towers at any time and prohibit cl...

Страница 6: ......

Страница 7: ...7 1 Wiring to Datalogger 7 7 2 Datalogger Programming 7 7 2 1 VoltSE Instruction 7 7 3 Field Installation 8 7 3 1 Shield Installation 10 7 3 1 1 Installation in a RAD10E 10 Plate Shield 10 7 3 1 2 In...

Страница 8: ...n Shield on a tripod mast 11 Tables 7 1 Wire Color Function and Datalogger Connection for Single Ended Measurement 7 CRBasic Examples B 1 CR1000 Program Measuring the EE181 B 1 B 2 CR6 Program Measuri...

Страница 9: ...nt Santoprene rubber which composes the black outer jacket of the EE181 cable will support combustion in air It is used because of its resistance to temperature extremes moisture and UV degradation It...

Страница 10: ...Short Cut is an easy way to program your datalogger to measure the EE181 and assign datalogger wiring terminals Short Cut is available as a download on www campbellsci com and the ResourceDVD It is in...

Страница 11: ...vices list select the Sensors Meteorological Relative Humidity Temperature EE181 Temperature and Relative Humidity Sensor folder Choose either constant power or panel switched power uses less current...

Страница 12: ...r 7 If the sensor is connected to the datalogger as shown in the wiring diagram in step 4 check the output of the sensor in the datalogger support software data display to make sure it is making reaso...

Страница 13: ...290 g 10 2 oz Housing Plastic material IP65 Filter 30 m pore size stainless steel mesh Power Consumption 1 2 mA at 12 V Supply Voltage using CSI cable 7 to 30 Vdc 12 Vdc recommended Start Up Time 2 s...

Страница 14: ...5 0 015 RH reading RH Typical Long Term Stability 1 RH per year Sensor Time Constant 63 of a 35 to 80 RH step change 1 m s air flow at sensor Standard PE Filter 22 s Optional Teflon Filter 30 s The a...

Страница 15: ...ded when Creating a program for a new datalogger installation Adding sensors to an existing datalogger program If your data acquisition requirements are simple you can probably create and maintain a d...

Страница 16: ...be located at a distance of at least four times the height of any nearby obstruction and at least 30 m EPA from large paved areas Sensors should be protected from thermal radiation and adequately ven...

Страница 17: ...around three to four plates down from the top of the shield See FIGURE 7 1 FIGURE 7 1 EE181 Sensor Placement in a RAD10E Multi plate Shield Tools required for installing an EE181 sensor in a radiation...

Страница 18: ...land until it firmly grips the body of the probe Use an adjustable wrench if necessary but do not overtighten the nut 7 3 1 2 Installation in an RM Young 41003 5 10 Plate Shield Do not mount the shiel...

Страница 19: ...V terminal to conserve battery life When power is switched a two second warm up period is required This is programmed with the Delay instruction using 0 for the delay option 8 3 Long Cable Lengths Lon...

Страница 20: ...page at the beginning of this manual for more information 9 1 Troubleshooting Symptom Relative Humidity is reported as 9999 NAN 40 C or 0 1 Check that the sensor is wired to the correct analog input...

Страница 21: ...r depends strongly on the temperature and humidity conditions and the length of the pollutant influence The sensor should be calibrated annually Please obtain an RMA number before returning the EE181...

Страница 22: ...iss A 1977 Algorithms for the calculation of moist air properties on a hand calculator Amer Soc Ag Eng 20 1133 1136 WMO 2008 Guide to Meteorological Instruments and Methods of Observation World Meteor...

Страница 23: ...ram and exit Short Cut Make note of the file name used when saving the Short Cut program 2 Open CRBasic Editor 3 Click File Open Assuming the default paths were used when Short Cut was installed navig...

Страница 24: ......

Страница 25: ...Terminal Red Power SW12 Yellow Temperature signal SE1 Blue Relative Humidity signal SE2 Black Power Ground Ground Symbol Clear Shield Ground Symbol Public AirTC Units AirTC C Public RH Units RH DataTa...

Страница 26: ...ower SW12 1 Yellow Temperature signal U1 Blue Relative Humidity signal U2 Black Power Ground Ground Symbol Clear Shield Ground Symbol Public AirTC Units AirTC C Public RH Units RH DataTable Temp_RH Tr...

Страница 27: ...hout causing a change absolute humidity For example for an air temperature of 20 C and a vapor pressure of 1 17 kPa the saturation vapor pressure is 2 34 kPa and the relative humidity is 50 If the air...

Страница 28: ...e RH must be a fraction e_kPa e_Sat RH 100 CallTable Temp_RH NextScan EndProg CRBasic Example C 2 CR6 Program that Computes Vapor Pressure and Saturation Vapor Pressure Program measures EE181 with sin...

Страница 29: ...ed water vapor pressure above liquid water even at temperatures below 0 C where ice might form This is the common way to express relative humidity and is as defined by the World Meteorological Organiz...

Страница 30: ...Appendix C Absolute Humidity C 4...

Страница 31: ......

Страница 32: ...ua Apinag s nbr 2018 Perdizes CEP 01258 00 S o Paulo SP BRASIL www campbellsci com br vendas campbellsci com br Campbell Scientific Canada Corp 14532 131 Avenue NW Edmonton AB T5L 4X4 CANADA www campb...

Отзывы: