PowerConnect B-Series FCX Configuration Guide
53-1002266-01
VLAN overview
13
FIGURE 90
VLANs configured across multiple devices
Support for 802.1Q-in-Q tagging
Dell PowerConnect devices provide finer granularity for configuring 802.1Q tagging, enabling you to
configure 802.1Q tag-types on a group of ports, thereby enabling the creation of two identical
802.1Q tags (802.1Q-in-Q tagging) on a single device. This enhancement improves SAV
interoperability between Dell PowerConnect devices and other vendors’ devices that support the
802.1Q tag-types, but are not very flexible with the tag-types they accept.
•
PowerConnect B-Series FCX devices support one value for tag-type, which is defined at the
global level, and one value for tag-profile, which is defined at the global and interface level of
the CLI.
802.1 Q-in-Q tagging for PowerConnect B-Series FCX Series devices
The following enhancements allow the PowerConnect B-Series FCX devices, including those in an
IronStack, to use Q-in-Q and SAV, by allowing the changing of a tag profile for ports:
•
In addition to the default tag type 0x8100, you can now configure one additional global tag
profile with a number from 0xffff.
•
Tag profiles on a single port, or a group of ports can be configured to point to the global tag
profile.
For example applications and configuration details, refer to
“Configuring 802.1Q-in-Q tagging”
on
page 484.
To configure a global tag profile, enter the following command in the configuration mode.
PowerConnect(config)# tag-profile 9500
Syntax: [no] tag-profile
<tag-no>
<tag-no>
- the number of the tag, can be 0x8100 (default), or 0xffff
U
s
er-config
u
red port-b
as
ed VLAN
T
= 802.1Q t
a
gged port
T
T
T
T
T
T
Segment 1
Segment 2
T
Segment 2
Segment 1
T
a
gging i
s
req
u
ired for the port
s
on Segment 1 bec
aus
e the port
s
a
re in m
u
ltiple port-b
as
ed VLAN
s
.
Witho
u
t t
a
gging,
a
device receiving
VLAN tr
a
ffic from the other device
wo
u
ld not be
su
re which VLAN the
tr
a
ffic i
s
for.
T
a
gging i
s
not req
u
ired for the port
s
on Segment 2 bec
aus
e e
a
ch port i
s
in only one port-b
as
ed VLAN.
Содержание PowerConnect B-FCXs
Страница 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Страница 136: ...94 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Viewing information about software licenses 4 ...
Страница 228: ...186 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 229: ...PowerConnect B Series FCX Configuration Guide 187 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 230: ...188 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Страница 346: ...304 PowerConnect B Series FCX Configuration Guide 53 1002266 01 802 1s Multiple Spanning Tree Protocol 8 ...
Страница 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Страница 424: ...382 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Virtual Switch Redundancy Protocol VSRP 10 ...
Страница 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Страница 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Страница 674: ...632 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Enabling or disabling layer 2 switching 19 ...
Страница 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Страница 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Страница 768: ...726 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing cached LLDP neighbor information 24 ...
Страница 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Страница 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Страница 962: ...920 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying CPU utilization statistics 28 ...
Страница 1022: ...980 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying OSPF information 29 ...
Страница 1142: ...1100 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing diagnostic buffers 30 ...
Страница 1258: ...1216 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Using Secure copy with SSH2 33 ...
Страница 1314: ...1272 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying port security information 35 ...
Страница 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Страница 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...
Страница 1422: ...1380 PowerConnect B Series FCX Configuration Guide 53 1002266 01 SNMP v3 Configuration examples 40 ...