PowerConnect B-Series FCX Configuration Guide
731
53-1002266-01
Changing global IP multicast parameters
25
NOTE
You do not need to reload the software for these changes to take effect.
Defining the maximum number of DVMRP cache entries
The DVMRP cache system parameter defines the maximum number of repeated DVMRP traffic
being sent from the same source address and being received by the same destination address. To
define this maximum, enter a command such as the following.
PowerConnect(config)#system-max dvmrp-mcache 500
Syntax: system-max dvmrp-mcache
<num>
The
<num>
parameter specifies the maximum number of multicast cache entries for DVMRP.
Enter a number from 128 – 4096. The default is 512.
Defining the maximum number of PIM cache entries
The PIM cache system parameter defines the maximum number of repeated PIM traffic being sent
from the same source address and being received by the same destination address. To define this
maximum, enter a command such as the following.
PowerConnect(config)#system-max pim-mcache 999
Syntax: system-max pim-mcache
<num>
The
<num>
parameter specifies the maximum number of multicast cache entries for PIM. Enter a
number from 256 – 4096. The default is 1024.
Changing IGMP V1 and V2 parameters
IGMP allows routers to limit the multicast of IGMP packets to only those ports on the router that are
identified as IP Multicast members. This section applies to Dell PowerConnect devices that support
IGMP versions 1 and 2.
The router actively sends out host queries to identify IP Multicast groups on the network, inserts
the group information in an IGMP packet, and forwards the packet to IP Multicast neighbors.
The following IGMP V1 and V2 parameters apply to PIM and DVMRP:
•
IGMP query interval – Specifies how often the Layer 3 Switch queries an interface for group
membership.
•
IGMP group membership time – Specifies how many seconds an IP Multicast group can remain
on a Layer 3 Switch interface in the absence of a group report.
•
IGMP maximum response time – Specifies how many seconds the Layer 3 Switch will wait for
an IGMP response from an interface before concluding that the group member on that
interface is down and then removing the interface from the group.
To change these parameters, you must first enable IP multicast routing by entering the following CLI
command at the global CLI level.
PowerConnect(config)#ip multicast-routing
Syntax: [no] ip multicast-routing
Содержание PowerConnect B-FCXs
Страница 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Страница 136: ...94 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Viewing information about software licenses 4 ...
Страница 228: ...186 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 229: ...PowerConnect B Series FCX Configuration Guide 187 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 230: ...188 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Страница 346: ...304 PowerConnect B Series FCX Configuration Guide 53 1002266 01 802 1s Multiple Spanning Tree Protocol 8 ...
Страница 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Страница 424: ...382 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Virtual Switch Redundancy Protocol VSRP 10 ...
Страница 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Страница 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Страница 674: ...632 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Enabling or disabling layer 2 switching 19 ...
Страница 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Страница 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Страница 768: ...726 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing cached LLDP neighbor information 24 ...
Страница 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Страница 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Страница 962: ...920 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying CPU utilization statistics 28 ...
Страница 1022: ...980 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying OSPF information 29 ...
Страница 1142: ...1100 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing diagnostic buffers 30 ...
Страница 1258: ...1216 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Using Secure copy with SSH2 33 ...
Страница 1314: ...1272 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying port security information 35 ...
Страница 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Страница 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...
Страница 1422: ...1380 PowerConnect B Series FCX Configuration Guide 53 1002266 01 SNMP v3 Configuration examples 40 ...