1392
PowerConnect B-Series FCX Configuration Guide
53-1002266-01
Syslog messages
41
TABLE 239
Syslog messages
Message level
Message
Explanation
Alert
<num-modules>
modules and 1 power
supply, need more power supply!!
Indicates that the chassis needs more
power supplies to run the modules in the
chassis.
The
<num-modules>
parameter indicates
the number of modules in the chassis.
Alert
Fan
<num>, <location>
, failed
A fan has failed.
The
<num>
is the fan number.
The
<location>
describes where the failed
fan is in the chassis.
Alert
MAC Authentication failed for
<mac-address>
on
<portnum>
RADIUS authentication was successful for
the specified
<mac-address>
on the
specified
<portnum>
; however, the VLAN
returned in the RADIUS Access-Accept
message did not refer to a valid VLAN or
VLAN ID on the Dell PowerConnect device.
This is treated as an authentication failure.
Alert
MAC Authentication failed for
<mac-address>
on
<portnum>
(Invalid User)
RADIUS authentication failed for the
specified
<mac-address>
on the specified
<portnum>
because the MAC address sent
to the RADIUS server was not found in the
RADIUS server users database.
Alert
MAC Authentication failed for
<mac-address>
on
<portnum>
(No VLAN
Info received from RADIUS server)
RADIUS authentication was successful for
the specified
<mac-address>
on the
specified
<portnum>
; however, dynamic
VLAN assignment was enabled for the port,
but the RADIUS Access-Accept message did
not include VLAN information. This is
treated as an authentication failure.
Alert
MAC Authentication failed for
<mac-address>
on
<portnum>
(Port is
already in another radius given vlan)
RADIUS authentication was successful for
the specified
<mac-address>
on the
specified
<portnum>
; however, the RADIUS
Access-Accept message specified a VLAN
ID, although the port had previously been
moved to a different RADIUS-assigned
VLAN. This is treated as an authentication
failure.
Alert
MAC Authentication failed for
<mac-address>
on
<portnum>
(RADIUS
given vlan does not exist)
RADIUS authentication was successful for
the specified
<mac-address>
on the
specified
<portnum>
; however, the RADIUS
Access-Accept message specified a VLAN
that does not exist in the Dell PowerConnect
configuration. This is treated as an
authentication failure.
Alert
MAC Authentication failed for
<mac-address>
on
<portnum>
(RADIUS
given VLAN does not match with TAGGED
vlan)
Multi-device port authentication failed for
the
<mac-address>
on a tagged port
because the packet with this MAC address
as the source was tagged with a VLAN ID
different from the RADIUS-supplied VLAN
ID.
Содержание PowerConnect B-FCXs
Страница 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Страница 136: ...94 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Viewing information about software licenses 4 ...
Страница 228: ...186 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 229: ...PowerConnect B Series FCX Configuration Guide 187 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 230: ...188 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Страница 346: ...304 PowerConnect B Series FCX Configuration Guide 53 1002266 01 802 1s Multiple Spanning Tree Protocol 8 ...
Страница 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Страница 424: ...382 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Virtual Switch Redundancy Protocol VSRP 10 ...
Страница 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Страница 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Страница 674: ...632 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Enabling or disabling layer 2 switching 19 ...
Страница 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Страница 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Страница 768: ...726 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing cached LLDP neighbor information 24 ...
Страница 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Страница 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Страница 962: ...920 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying CPU utilization statistics 28 ...
Страница 1022: ...980 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying OSPF information 29 ...
Страница 1142: ...1100 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing diagnostic buffers 30 ...
Страница 1258: ...1216 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Using Secure copy with SSH2 33 ...
Страница 1314: ...1272 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying port security information 35 ...
Страница 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Страница 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...
Страница 1422: ...1380 PowerConnect B Series FCX Configuration Guide 53 1002266 01 SNMP v3 Configuration examples 40 ...