424
PowerConnect B-Series FCX Configuration Guide
53-1002266-01
Displaying and determining the status of aggregate links
12
Displaying link aggregation and port status information for PowerConnect
Stackable devices
To display link aggregation information for devices in an IronStack, enter the show link-aggregate
command. The output for an Ironstack resembles the following.
Displaying LACP status information
Use the show trunk command to determine the status of LACP. Refer to
“Displaying trunk group
configuration information”
on page 408.
Def
Indicates whether the port is using default link aggregation values. The port uses default values
if it has not received link aggregation information through LACP from the port at the remote end
of the link. This field can have one of the following values:
•
Def – The port has not received link aggregation values from the port at the other end of the
link and is therefore using its default link aggregation LACP settings.
•
No – The port has received link aggregation information from the port at the other end of
the link and is using the settings negotiated with that port.
Exp
Indicates whether the negotiated link aggregation settings have expired. The settings expire if
the port does not receive an LACPDU message from the port at the other end of the link before
the message timer expires. This field can have one of the following values:
•
Exp – The link aggregation settings this port negotiated with the port at the other end of the
link have expired. The port is now using its default link aggregation settings.
•
No – The link aggregation values that this port negotiated with the port at the other end of
the link have not expired, so the port is still using the negotiated settings.
Ope
•
Ope (operational) - The port is operating normally.
•
Ina (inactive) - The port is inactive because the port on the other side of the link is down or
has stopped transmitting LACP packets.
•
Blo (blocked) - The port is blocked because the adjacent port is not configured with link
aggregation or because it is not able to join a trunk group. To unblock the port and bring it to
an operational state, enable link aggregation on the adjacent port and ensure that the ports
have the same key.
TABLE 75
CLI display of link aggregation information (Continued)
This field...
Displays...
PowerConnect(config)#show link-aggregate
System ID: 0012.f2e5.a200
Long timeout: 120, default: 120
Short timeout: 3, default: 3
Port [Sys P] [Port P] [ Key ] [Act][Tio][Agg][Syn][Col][Dis][Def][Exp][Ope]
1/1/1 1 1 13000 Yes L Agg Syn Col Dis No No Ope
2/1/1 1 1 13000 Yes L Agg Syn Col Dis No No Ope
3/1/1 1 1 13000 Yes L Agg Syn Col Dis No No Ope
4/1/1 1 1 13000 Yes L Agg Syn Col Dis No No Ope
Содержание PowerConnect B-FCXs
Страница 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Страница 136: ...94 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Viewing information about software licenses 4 ...
Страница 228: ...186 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 229: ...PowerConnect B Series FCX Configuration Guide 187 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 230: ...188 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Страница 346: ...304 PowerConnect B Series FCX Configuration Guide 53 1002266 01 802 1s Multiple Spanning Tree Protocol 8 ...
Страница 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Страница 424: ...382 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Virtual Switch Redundancy Protocol VSRP 10 ...
Страница 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Страница 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Страница 674: ...632 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Enabling or disabling layer 2 switching 19 ...
Страница 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Страница 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Страница 768: ...726 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing cached LLDP neighbor information 24 ...
Страница 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Страница 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Страница 962: ...920 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying CPU utilization statistics 28 ...
Страница 1022: ...980 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying OSPF information 29 ...
Страница 1142: ...1100 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing diagnostic buffers 30 ...
Страница 1258: ...1216 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Using Secure copy with SSH2 33 ...
Страница 1314: ...1272 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying port security information 35 ...
Страница 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Страница 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...
Страница 1422: ...1380 PowerConnect B Series FCX Configuration Guide 53 1002266 01 SNMP v3 Configuration examples 40 ...