PowerConnect B-Series FCX Configuration Guide
1321
53-1002266-01
Configuring web authentication options
37
Syntax: [no] accounting
Enter the no accounting command to disable RADIUS accounting for Web Authentication.
Changing the login mode (HTTPS or HTTP)
Web Authentication can be configured to use secure (HTTPS) or non-secure (HTTP) login and logout
pages. By default, HTTPS is used.
Figure 167
shows an example Login page.
To change the login mode to non-secure (HTTP), enter the following command.
PowerConnect(config-vlan-10-webauth)#no secure-login
To revert back to secure mode, enter the following command.
PowerConnect(config-vlan-10-webauth)#secure-login
Syntax: [no] secure-login
Specifying trusted ports
You can configure certain ports of a Web Authentication VLAN as trusted ports. All hosts connected
to the trusted ports need not authenticate and are automatically allowed access to the network.
To create a list of trusted ports, enter commands such as the following.
PowerConnect(config-vlan-10-webauth)#trust-port ethernet 3
PowerConnect(config-vlan-10-webauth)#trust port ethernet 6 to 10
The above commands configure ports 3 and 6 – 10 as trusted ports.
Syntax: trust-port ethernet
<port>
[to
<port>
]
Specify the
<port>
variable in the following formats:
•
PowerConnect B-Series FCX stackable switches –
<stack-unit/slotnum/portnum>
Specifying hosts that are permanently authenticated
Certain hosts, such as DHCP server, gateway, printers, may need to be permanently authenticated.
Typically, these hosts are managed by the network administrator and are considered to be
authorized hosts. Also, some of these hosts (such as printers) may not have a Web browser and will
not be able to perform the Web Authentication.
To permanently authenticate these types of hosts, enter a command such as the following at the
"webauth" configuration level.
PowerConnect(config-vlan-10-webauth)#add mac 0004.80eb.2d14 duration 0
PowerConnect(config-vlan-10-webauth)#add mac 0007.e90e.de3b duration 0
Syntax: [no] add mac
<mac-address>
duration
<seconds>
| ethernet
<port>
duration
<seconds>
Syntax: no add mac
<mac-address>
Specify the
<port>
variable in the following formats:
•
PowerConnect B-Series FCX stackable switches –
<stack-unit/slotnum/portnum>
<seconds>
specifies how long the MAC address remains authenticated. Enter 0 – 128000
seconds. The default is the current value of reauth-time. A value of "0" means that Web
Authentication for the MAC address will not expire.
Содержание PowerConnect B-FCXs
Страница 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Страница 136: ...94 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Viewing information about software licenses 4 ...
Страница 228: ...186 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 229: ...PowerConnect B Series FCX Configuration Guide 187 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 230: ...188 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Страница 346: ...304 PowerConnect B Series FCX Configuration Guide 53 1002266 01 802 1s Multiple Spanning Tree Protocol 8 ...
Страница 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Страница 424: ...382 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Virtual Switch Redundancy Protocol VSRP 10 ...
Страница 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Страница 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Страница 674: ...632 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Enabling or disabling layer 2 switching 19 ...
Страница 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Страница 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Страница 768: ...726 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing cached LLDP neighbor information 24 ...
Страница 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Страница 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Страница 962: ...920 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying CPU utilization statistics 28 ...
Страница 1022: ...980 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying OSPF information 29 ...
Страница 1142: ...1100 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing diagnostic buffers 30 ...
Страница 1258: ...1216 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Using Secure copy with SSH2 33 ...
Страница 1314: ...1272 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying port security information 35 ...
Страница 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Страница 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...
Страница 1422: ...1380 PowerConnect B Series FCX Configuration Guide 53 1002266 01 SNMP v3 Configuration examples 40 ...