PowerConnect B-Series FCX Configuration Guide
1023
53-1002266-01
Optional configuration tasks
30
•
Configure the confederation ID. The confederation ID is the AS number by which BGP switches
outside the confederation know the confederation. Thus, a BGP switch outside the
confederation is not aware and does not care that your BGP switches are in multiple
sub-autonomous systems. BGP switches use the confederation ID when communicating with
switches outside the confederation. The confederation ID must be different from the sub-AS
numbers.
•
Configure the list of the sub-AS numbers that are members of the confederation. All the
switches within the same sub-AS use IBGP to exchange switch information. Switches in
different sub-autonomous systems within the confederation use EBGP to exchange switch
information.
To configure four Layer 3 Switches to be a member of confederation 10 (as shown in
Figure 148
),
consisting of two sub-autonomous systems (64512 and 64513), enter commands such as the
following.
Commands for router A
PowerConnectA(config)#router bgp
PowerConnectA(config-bgp-router)#local-as 64512
PowerConnectA(config-bgp-router)#confederation identifier 10
PowerConnectA(config-bgp-router)#confederation peers 64512 64513
PowerConnectA(config-bgp-router)#write memory
Syntax: local-as
<num>
The
<num>
parameter with the local-as command indicates the AS number for the BGP switches
within the sub-AS. You can specify a number from 1 through 65535. Dell recommends that you use
a number within the range of well-known private autonomous systems, 64512 through 65535.
Syntax: confederation identifier
<num>
The
<num>
parameter with the confederation identifier command indicates the confederation
number. The confederation ID is the AS number by which BGP switches outside the confederation
know the confederation. Thus, a BGP switch outside the confederation is not aware and does not
care that your BGP switches are in multiple sub-autonomous systems. BGP switches use the
confederation ID when communicating with switches outside the confederation. The confederation
ID must be different from the sub-AS numbers. You can specify a number from 1 through 65535.
Syntax: confederation peers
<num> [<num>
…]
The
<num>
parameter with the confederation peers command indicates the sub-AS numbers for
the sub-autonomous systems in the confederation. You must specify all the sub-autonomous
systems contained in the confederation. All the switches within the same sub-AS use IBGP to
exchange switch information. Switches in different sub-autonomous systems within the
confederation use EBGP to exchange switch information. You can specify a number from 1 through
65535.
Commands for router B
PowerConnectB(config)#router bgp
PowerConnectB(config-bgp-router)#local-as 64512
PowerConnectB(config-bgp-router)#confederation identifier 10
PowerConnectB(config-bgp-router)#confederation peers 64512 64513
PowerConnectB(config-bgp-router)#write memory
Содержание PowerConnect B-FCXs
Страница 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Страница 136: ...94 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Viewing information about software licenses 4 ...
Страница 228: ...186 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 229: ...PowerConnect B Series FCX Configuration Guide 187 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 230: ...188 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Страница 346: ...304 PowerConnect B Series FCX Configuration Guide 53 1002266 01 802 1s Multiple Spanning Tree Protocol 8 ...
Страница 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Страница 424: ...382 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Virtual Switch Redundancy Protocol VSRP 10 ...
Страница 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Страница 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Страница 674: ...632 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Enabling or disabling layer 2 switching 19 ...
Страница 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Страница 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Страница 768: ...726 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing cached LLDP neighbor information 24 ...
Страница 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Страница 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Страница 962: ...920 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying CPU utilization statistics 28 ...
Страница 1022: ...980 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying OSPF information 29 ...
Страница 1142: ...1100 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing diagnostic buffers 30 ...
Страница 1258: ...1216 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Using Secure copy with SSH2 33 ...
Страница 1314: ...1272 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying port security information 35 ...
Страница 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Страница 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...
Страница 1422: ...1380 PowerConnect B Series FCX Configuration Guide 53 1002266 01 SNMP v3 Configuration examples 40 ...