PowerConnect B-Series FCX Configuration Guide
277
53-1002266-01
PVST/PVST+ compatibility
8
FIGURE 53
Interaction of IEEE 802.1Q, PVST, and PVST+ regions
VLAN tags and dual mode
The
dual-mode
feature enables a port to send and receive both tagged and untagged frames.
When the dual-mode feature is enabled on a port, the port is an untagged member of one of its
VLANs and is at the same time a tagged member of all its other VLANs. The untagged frames are
supported on the port
Port Native VLAN
.
The dual-mode feature must be enabled on a Dell PowerConnect port in order to interoperate with
another vendor device. Some vendors use VLAN 1 by default to support the IEEE 802.1Q-based
standard spanning tree protocols, such as 802.1d and 802.1w for sending untagged frames on
VLAN 1. On Dell PowerConnect switches, by default, the
Port Native VLAN
is the same as the
Default VLAN
, which is VLAN 1. Thus, to support IEEE 802.1Q in a typical configuration, a port must
be able to send and receive untagged frames for VLAN 1 and tagged frames for the other VLANs,
and interoperate with other vendor devices using VLAN 1.
If you want to use tagged frames on VLAN 1, you can change the default VLAN ID to an ID other
than 1. You also can specify the VLAN on which you want the port to send and receive untagged
frames (the Port Native VLAN). The Port Native VLAN ID does not need to be the same as the
default VLAN. Make sure that the untagged (native) VLAN is also changed on the interoperating
vendor side to match that on the Dell PowerConnect side.
To support the IEEE 802.1Q with non-standard proprietary protocols such as PVST and PVST+, a
port must always send and receive untagged frames on VLAN 1 on both sides. In this case, enable
the dual-mode 1 feature to allow untagged BPDUs on VLAN 1and use Native VLAN 1 on the
interoperating vendor side. You should not use VLAN 1 for tagged frames in this case.
PVST+Region
IEEE 802.1Q Region
PVST+Region
PVST Region
PVST BPDUs
(over ISL trunks)
PVST BPDUs
(over ISL trunks)
Do not
connect
d
ua
l mode
port
d
ua
l mode
port
802.1D BPDUs
802.1D BPDUs
PVST BPDUs tunneled through
the IEEE 802.1Q region
Содержание PowerConnect B-FCXs
Страница 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Страница 136: ...94 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Viewing information about software licenses 4 ...
Страница 228: ...186 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 229: ...PowerConnect B Series FCX Configuration Guide 187 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 230: ...188 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Страница 346: ...304 PowerConnect B Series FCX Configuration Guide 53 1002266 01 802 1s Multiple Spanning Tree Protocol 8 ...
Страница 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Страница 424: ...382 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Virtual Switch Redundancy Protocol VSRP 10 ...
Страница 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Страница 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Страница 674: ...632 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Enabling or disabling layer 2 switching 19 ...
Страница 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Страница 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Страница 768: ...726 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing cached LLDP neighbor information 24 ...
Страница 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Страница 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Страница 962: ...920 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying CPU utilization statistics 28 ...
Страница 1022: ...980 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying OSPF information 29 ...
Страница 1142: ...1100 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing diagnostic buffers 30 ...
Страница 1258: ...1216 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Using Secure copy with SSH2 33 ...
Страница 1314: ...1272 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying port security information 35 ...
Страница 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Страница 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...
Страница 1422: ...1380 PowerConnect B Series FCX Configuration Guide 53 1002266 01 SNMP v3 Configuration examples 40 ...