928
PowerConnect B-Series FCX Configuration Guide
53-1002266-01
Overview of OSPF
29
that flush the duplicate AS External LSAs have more memory for other OSPF data. In
Figure 141
,
since Router D has a higher router ID than Router E, Router D floods the AS External LSAs for
Router F to Routers A, B, and C. Router E flushes the equivalent AS External LSAs from its
database.
Algorithm for AS External LSA reduction
Figure 141
shows an example in which the normal AS External LSA reduction feature is in effect.
The behavior changes under the following conditions:
•
There is one ASBR advertising (originating) a route to the external destination, but one of the
following happens:
•
A second ASBR comes on-line
•
A second ASBR that is already on-line begins advertising an equivalent route to the same
destination.
In either case above, the router with the higher router ID floods the AS External LSAs and the
other router flushes its equivalent AS External LSAs. For example, if Router D is offline, Router
E is the only source for a route to the external routing domain. When Router D comes on-line, it
takes over flooding of the AS External LSAs to Router F, while Router E flushes its equivalent AS
External LSAs to Router F.
•
One of the ASBRs starts advertising a route that is no longer equivalent to the route the other
ASBR is advertising. In this case, the ASBRs each flood AS External LSAs. Since the LSAs
either no longer have the same cost or no longer have the same next-hop router, the LSAs are
no longer equivalent, and the LSA reduction feature no longer applies.
•
The ASBR with the higher router ID becomes unavailable or is reconfigured so that it is no
longer an ASBR. In this case, the other ASBR floods the AS External LSAs. For example, if
Router D goes off-line, then Router E starts flooding the AS with AS External LSAs for the route
to Router F.
Support for OSPF RFC 2328 Appendix E
Dell PowerConnect devices provide support for Appendix E in OSPF RFC 2328. Appendix E
describes a method to ensure that an OSPF router (such as a Layer 3 Switch) generates unique link
state IDs for type-5 (External) link state advertisements (LSAs) in cases where two networks have
the same network address but different network masks.
NOTE
Support for Appendix E of RFC 2328 is enabled automatically and cannot be disabled. No user
configuration is required.
Normally, an OSPF router uses the network address alone for the link state ID of the link state
advertisement (LSA) for the network. For example, if the router needs to generate an LSA for
network 10.1.2.3 255.0.0.0, the router generates ID 10.1.2.3 for the LSA.
However, suppose that an OSPF router needs to generate LSAs for all the following networks:
•
10.0.0.0 255.0.0.0
•
10.0.0.0 255.255.0.0
•
10.0.0.0 255.255.255.0
Содержание PowerConnect B-FCXs
Страница 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Страница 136: ...94 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Viewing information about software licenses 4 ...
Страница 228: ...186 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 229: ...PowerConnect B Series FCX Configuration Guide 187 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 230: ...188 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Страница 346: ...304 PowerConnect B Series FCX Configuration Guide 53 1002266 01 802 1s Multiple Spanning Tree Protocol 8 ...
Страница 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Страница 424: ...382 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Virtual Switch Redundancy Protocol VSRP 10 ...
Страница 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Страница 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Страница 674: ...632 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Enabling or disabling layer 2 switching 19 ...
Страница 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Страница 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Страница 768: ...726 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing cached LLDP neighbor information 24 ...
Страница 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Страница 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Страница 962: ...920 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying CPU utilization statistics 28 ...
Страница 1022: ...980 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying OSPF information 29 ...
Страница 1142: ...1100 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing diagnostic buffers 30 ...
Страница 1258: ...1216 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Using Secure copy with SSH2 33 ...
Страница 1314: ...1272 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying port security information 35 ...
Страница 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Страница 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...
Страница 1422: ...1380 PowerConnect B Series FCX Configuration Guide 53 1002266 01 SNMP v3 Configuration examples 40 ...