PowerConnect B-Series FCX Configuration Guide
307
53-1002266-01
MAC learning rate control
9
You can also enable and disable spanning tree on a port-based VLAN and on an individual port
basis, and enable advanced STP features. Refer to
Chapter 8, “Configuring Spanning Tree Protocol
(STP) Related Features”
.
Modifying STP bridge and port parameters
You can modify the following STP Parameters:
•
Bridge parameters – forward delay, maximum age, hello time, and priority
•
Port parameters – priority and path cost
For configuration details, refer to
“Changing STP bridge and port parameters”
on page 210.
MAC learning rate control
You can set a rate limit to control CPU address updating. The range for this rate limit is 200 -
50,000 per second. The MAC learning rate limit applies to each packet processor, which means
that for a system with two packet processors, each processor can send address messages to the
CPU at the established rate limit.
Syntax: [no] cpu-limit addr-msgs
<msgsRateLimit>
NOTE
Actual rates in hardware may have a variance of +200 or -100.
Changing the MAC age time and disabling MAC address learning
To change the MAC address age timer, enter a command such as the following.
PowerConnect(config)#mac-age-time 60
Syntax: [no] mac-age-time
<secs>
<secs>
specifies the number of seconds. Possible values differ depending on the version of
software running on your device, as follows:
•
On PowerConnect B-Series FCX devices, learned MAC address entries do not age out until they
are unused for 300 – 600 seconds. If necessary, you can change the MAC address age timer
to 0 or a value from 60 – 600 (seconds), in 60-second intervals. For example, you can specify
60 or 120, but not 100. If you set the MAC age time to 0, aging is disabled.
NOTES:
Usually, the actual MAC age time is from one to two times the configured value. For
example, if you set the MAC age timer to 60 seconds, learned MAC entries age out after remaining
unused for between 60 – 120 seconds. However, if all of the following conditions are met, then the
MAC entries age out after a longer than expected duration:
•
The MAC age timer is greater than 630 seconds.
•
The number of MAC entries is over 6000.
•
All MAC entries are learned from the same packet processor.
•
All MAC entries age out at the same time.
Содержание PowerConnect B-FCXs
Страница 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Страница 136: ...94 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Viewing information about software licenses 4 ...
Страница 228: ...186 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 229: ...PowerConnect B Series FCX Configuration Guide 187 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 230: ...188 PowerConnect B Series FCX Configuration Guide 53 1002266 01 PowerConnect B Series FCX hitless stacking 5 ...
Страница 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Страница 346: ...304 PowerConnect B Series FCX Configuration Guide 53 1002266 01 802 1s Multiple Spanning Tree Protocol 8 ...
Страница 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Страница 424: ...382 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Virtual Switch Redundancy Protocol VSRP 10 ...
Страница 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Страница 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Страница 674: ...632 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Enabling or disabling layer 2 switching 19 ...
Страница 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Страница 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Страница 768: ...726 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing cached LLDP neighbor information 24 ...
Страница 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Страница 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Страница 962: ...920 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying CPU utilization statistics 28 ...
Страница 1022: ...980 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying OSPF information 29 ...
Страница 1142: ...1100 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Clearing diagnostic buffers 30 ...
Страница 1258: ...1216 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Using Secure copy with SSH2 33 ...
Страница 1314: ...1272 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Displaying port security information 35 ...
Страница 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Страница 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...
Страница 1422: ...1380 PowerConnect B Series FCX Configuration Guide 53 1002266 01 SNMP v3 Configuration examples 40 ...